Viper 540ESP Owner Manual - Page 11

Multi-Level Security Arming

Page 11 highlights

Multi-Level Security Arming Multi-Level Security Arming allows you to select which of the system's inputs or sensors will be active and which will be bypassed when the system is armed. (See Table of Zones in this guide.) Pressing (only in Standard Configuration) again within five seconds of arming the system will activate the Multi-Level Security feature. Each time is pressed again, a different security level is selected. The different security levels are selected as follows: s Pressing once: The siren chirps once. The system is armed. s Pressing a second time within five seconds: The siren chirps twice followed by a long chirp. Zone 2 is now bypassed. s Pressing a third time within five seconds: The siren chirps three times followed by a long chirp. Zone 4 is now bypassed. s Pressing a fourth time within five seconds: The siren chirps four times followed by a long chirp. Zones 2 and 4 are now bypassed. s Pressing a fifth time within five seconds: The siren chirps five times followed by a long chirp. All of the input zones, except for the ignition input zone, are now bypassed. NOTE: Multi-Level Security Arming only applies to a single arming cycle. Once the system is disarmed and then re-armed, all the zones will be active again. 10 © 1999 Directed Electronics, Inc.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37

10
©
1999 Directed Electronics, Inc.
Multi-Level Security Arming allows you to select which of the sys-
tem's inputs or sensors will be active and which will be bypassed
when the system is armed. (See Table of Zones in this guide.)
Pressing
(only in Standard Configuration) again within five
seconds of arming the system will activate the Multi-Level Security
feature. Each time
is pressed again, a different security level is
selected. The different security levels are selected as follows:
Pressing
once: The siren chirps once. The system is armed.
Pressing
a second time within five seconds: The siren
chirps twice followed by a long chirp. Zone 2 is now bypassed.
Pressing
a third time within five seconds: The siren chirps
three times followed by a long chirp. Zone 4 is now bypassed.
Pressing
a fourth time within five seconds: The siren
chirps four times followed by a long chirp. Zones 2 and 4 are
now bypassed.
Pressing
a fifth time within five seconds: The siren
chirps five times followed by a long chirp. All of the input
zones, except for the ignition input zone, are now
bypassed.
NOTE:
Multi-Level Security Arming only applies to a single arming cycle.
Once the system is disarmed and then re-armed, all the zones will be
active again.
Multi-Level Security Arming