Weslo Daybreak 408 Spa English Manual

Weslo Daybreak 408 Spa Manual

Weslo Daybreak 408 Spa manual content summary:

  • Weslo Daybreak 408 Spa | English Manual - Page 1
    , or if there are missing parts, we will guarantee complete satisfaction HOT LINE: 1-877-897-7493 Mon.-Fri., 6 a.m.-6 p.m. MST CAUTION Read all precautions and instructions in this manual before using this equipment. Save this manual for future reference. USER'S MANUAL Visit our website at www.weslo
  • Weslo Daybreak 408 Spa | English Manual - Page 2
    the Warning Sign 2 Important Safety Instructions 3 Before You Begin 6 Choosing a Location for the Hydrotherapy Spa 7 Assembly 8 Using the Hydrotherapy Spa 10 Spa Shell Diagram 11 Console Diagram 12 Maintenance 13 Maintenance Notes 16 Trouble-shooting 17 Part List 18 Exploded Drawing 19
  • Weslo Daybreak 408 Spa | English Manual - Page 3
    when it is filled with water. Make sure the location you select for the hydrotherapy spa will support this weight, plus the weight of the occupants. 6. Inspect and tighten all parts regularly. Replace any worn parts immediately. 7. DANGER-Risk of injury: Do not remove or alter the covers on the
  • Weslo Daybreak 408 Spa | English Manual - Page 4
    wire connector on the pump motor of this unit by a minimum No. 8 AWG (804 mm2) solid copper conductor (see instruction 24). 26. Do not operate the pump motor when the hydrotherapy spa is empty. The pump motor may be seriously damaged if it is operated without water circulating. 27. DANGER-Risk of
  • Weslo Daybreak 408 Spa | English Manual - Page 5
    exit the spa or hot tub, unawareness of impending hazard, fetal damage in pregnant women, physical inability to exit the spa or hot tub, and information on the decals. WARNING: Read all instructions before using the hydrotherapy spa. ICON assumes no responsibility for personal injury or
  • Weslo Daybreak 408 Spa | English Manual - Page 6
    selecting the WESLO® DAYBREAK 408 hydrotherapy spa. The DAYBREAK 408 spa offers the features and quality of a traditional hot tub at an benefit, read this manual carefully before using the DAYBREAK 408 spa. If you have additional questions, please call our Customer Service Department toll-free at
  • Weslo Daybreak 408 Spa | English Manual - Page 7
    must be able to support the weight of the hydrotherapy spa when it is filled with water, plus the weight of the occupants. The spa weighs approximately 1,800 that is built flush with the top of the spa, provided you leave access to the motor for service. 10.Be sure to note any other considerations,
  • Weslo Daybreak 408 Spa | English Manual - Page 8
    beginning assembly, carefully read the following information and instructions: • Place all parts in a cleared area and remove the packing materials from the spa shell. Do not dispose of the packing materials until assembly is completed and the spa is in operation. • During assembly, make sure that
  • Weslo Daybreak 408 Spa | English Manual - Page 9
    be easily serviced. Once the spa is filled, it will have to be drained to be moved. Using a garden hose or other clean water source, fill the spa. Do not use soft water. The spa may be filled with cool water; however, if warm or hot water is used, the spa will be ready to use
  • Weslo Daybreak 408 Spa | English Manual - Page 10
    "Non-chlorine Shox" bottle to the water in the spa. Allow the water to circulate for five minutes. You should now test the pH level of the water by using the included test strips. Refer to the test strip packaging for instructions on using the test strips. The pH reading should be
  • Weslo Daybreak 408 Spa | English Manual - Page 11
    on page 13). The temperature probe (C) reads the current water temperature. Use of the console (D) is explained on page 12 of this manual. The hydrotherapy spa offers automatic freeze protection. If the water temperature falls below 40˚F, the pump will begin circulating the water in order to prevent
  • Weslo Daybreak 408 Spa | English Manual - Page 12
    keep the filter and heat cycles from running, the power cord must be unplugged. Air Control: Determines the amount of air that is in the spa jet system during operation. If the control is turned to the left, the amount of air flowing through the jets will increase; if the control
  • Weslo Daybreak 408 Spa | English Manual - Page 13
    in a trisodium phos- phate (TSP) solution. Rinse the filter in clean water. • Replace the filter if needed (see ORDERING REPLACEMENT PARTS on the back cover). EVERY THREE MONTHS • Drain the spa and refill with clean water. Sanitize and test the pH of the water. • Check for any leaks around the pump
  • Weslo Daybreak 408 Spa | English Manual - Page 14
    problems can occur when the pH balance is not maintained within this range. If the pH level exceeds 7.8, dissolved minerals can build up and clog the plumbing in the spa jet unit. If the pH level falls below 7.2, the acid level in the water will begin to corrode the metal parts in the spa
  • Weslo Daybreak 408 Spa | English Manual - Page 15
    a garden hose to the valve on the drainage hose. 5. Open the valve by turning the knob counterclockwise. The water will begin to drain. 6. When the spa is empty, close the valve and remove the garden hose. Return the drainage hose to the clip and replace the access cover. 7. Refill the
  • Weslo Daybreak 408 Spa | English Manual - Page 16
    Maintenance Notes Maintenance is an important part of keeping your hydrotherapy spa in top operating condition. Use the space below to make any special notes you may want to remember for future reference, or to keep a maintenance log. 16
  • Weslo Daybreak 408 Spa | English Manual - Page 17
    Trouble-shooting Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service temperature. b. If you are using the hydrotherapy spa outdoors, it may take longer for the water
  • Weslo Daybreak 408 Spa | English Manual - Page 18
    time they will begin running the filter cycle. At any time after the spa jets have been shut off, the pump will begin cycling the water Water Test Strip Key User's Manual Large Warning Sign Warning Sign Foot Pump Note: "#" indicates a non-illustrated part. Specifications are subject to change
  • Weslo Daybreak 408 Spa | English Manual - Page 19
    Exploded Drawing-Model No. WLHS43082 R0401A 11 23 10 19 13 1 6 24 9 35 21 36 24 5 6 36 12 14 29 5 33 4 34 15 28 7 7 8 2 16 40 27 39 37 26 38 20 35 36 32 35 42 32 7 18 18 17 22 25 41 3 31 30 43 19
  • Weslo Daybreak 408 Spa | English Manual - Page 20
    WESLO® DAYBREAK 408) 3. The SERIAL NUMBER of the product (see the front cover of this manual) 4. The KEY NUMBER and DESCRIPTION of the desired part(s) (see the PART LIST and EXPLODED DRAWING on pages 18 and 19). Limited Massage Spa not provided by ICON authorized service personnel; to products used
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

USER’S MANUAL
QUESTIONS?
As a manufacturer, we are com-
mitted to providing complete
customer satisfaction. If you have
questions, or if there are missing
parts, we will guarantee complete
satisfaction through direct assis-
tance from our factory.
TO AVOID UNNECESSARY
DELAYS, PLEASE CALL DIRECT
TO OUR TOLL-FREE CUSTOMER
HOT LINE. The trained techni-
cians on our customer hot line
will provide immediate assis-
tance, free of charge to you.
CUSTOMER HOT LINE:
1-877-897-7493
Mon.–Fri., 6 a.m.–6 p.m. MST
Model No. WLHS43082
Serial No.
The serial number decal is on the
frame behind the access cover.
CAUTION
Read all precautions and instruc-
tions in this manual before using
this equipment. Save this manual
for future reference.
Serial Number Decal
Visit our website at
www.weslo.com
new products, prizes,
fitness tips, and much more!