Weslo Expert 350 English Manual - Page 7

Maintenance, Trouble, Shooting

Page 7 highlights

To use the lat bar with the upper cable, the chain must be attached between the lat bar and the cable using the two cable clips. The chain can be shortened by attaching the cable clips closer together along the chain. IMPORTANT: The proper length of chain between the lat bar and upper cable should be determined by the exercise to be performed. Adjust the length of chain until the lat bar is in a comfortable starting position. OPERATING AND "PARKING" THE PRESS ARM The press arm can be put in the operating position as described in the assembly instructions. For certain exercises, the press arm must be set out of the way, or "parked." To "park" the press arm, remove the pull pin and lift the press arm away from the press arm bracket. Insert the pull pin in ( the upper hole of the press arm bracket and rest the press arm on top of the pull pin. IMPORTANT: When the press arm Is in the "parked" position, do not put weight on the press arm or it will be damaged. MAINTENANCE AND TROUBLE-SHOOTING Inspect and tighten all parts of the system regularly. Replace any worn parts immediately. The outside of the system can be cleaned using a damp cloth and mild, non-abrasive detergent. Do not use solvents. ADJUSTING THE WEIGHT SYSTEM If there is slack in the weight system before the weight engages, the cables may need to be adjusted. To adjust the cables, a phillips screwdriver and two adjustable wrenches Lower Cable (not included) are required. Remove the four screws from the right side shield, and carefully move the side shield out of the way. Locate the "L"-shaped bracket with the four holes. The lower pulley cable will be bolted to the bracket. Remove the bolt and nut attaching the cable to the bracket. Move the cable to the next lower hole in the bracket, and re-attach the cable with the bolt and nut. Test the weight system before re- "L" Bracket attaching the side shield. If the motor stalls or hesitates, the cable is too tight. Move the cable to the next higher hole. If there is still slack in the cables, move the cable to the next lower hole as described above. If the cable is attached to the lowest hole in the bracket and there is still slack in the cables, the cables should be replaced (refer to the back cover). Re-attach the side shield. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

To
use
the
lat
bar
with
the
upper
cable,
the
chain
must
be
attached
between
the
lat
bar
and
the
cable
using
the
two
cable
clips.
The
chain
can
be
shortened
by
attaching
the
cable
clips
closer
together
along
the
chain.
IMPORTANT:
The
proper
length
of
chain
between
the
lat
bar
and
upper
cable
should
be
determined
by
the
exercise
to
be
per-
formed.
Adjust
the
length
of
chain
until
the
lat
bar
is
in
a
comfortable
starting
position.
OPERATING
AND
"PARKING"
THE
PRESS
ARM
The
press
arm
can be
put
in
the
operating
position
as
described
in
the
assembly
instructions.
For
certain
exercises,
the
press
arm
must
be
set
out
of
the
way,
or
"parked."
To
"park"
the
press
arm,
remove
the
pull
pin
and
lift
the
press
arm
away
from
the
press
arm
bracket.
Insert
the
pull
pin
in
the
upper
hole
of
the
press
arm
bracket
and
rest
the
press
arm
on
top
of
the
pull
pin.
IMPORTANT:
When
the
press
arm
Is
in
the
"parked"
position,
do
not
put
weight
on
the
press
arm
or
it
will
be
damaged.
(
MAINTENANCE
AND
TROUBLE
-SHOOTING
Inspect
and
tighten
all
parts
of
the
system
regularly.
Replace
any
worn
parts
immediately.
The
outside
of
the
system
can
be
cleaned
using
a
damp
cloth
and
mild,
non-abrasive
detergent.
Do
not
use
solvents.
ADJUSTING
THE
WEIGHT
SYSTEM
If
there
is
slack
in
the
weight
system
before
the
weight
engages,
the
cables
may
need
to
be
adjusted.
To
adjust
the
cables,
a
phillips
screwdriver
and
two
adjustable
wrenches
(not
included)
are
required.
Remove
the
four
screws
from
the
right
side
shield,
and
carefully
move
the
side
shield
out
of
the
way.
Locate
the
"L"
-shaped
bracket
with
the
four
holes.
The
lower
pulley
cable
will
be
bolted
to the
bracket.
Remove
the
bolt
and
nut
attaching
the
cable
to
the
bracket.
Move
the
cable
to
the
next
lower
hole
in
the
bracket,
and
re
-attach
the
cable
with
the
bolt
and
nut.
Test
the
weight
system
before
re-
attaching
the
side
shield.
If
the
motor
stalls
or
hesitates,
the
cable
is
too
tight.
Move
the
cable
to
the
next
higher
hole.
If
there
is
still
slack
in
the
cables,
move
the
cable
to
the
next
lower
hole
as
described
above.
If
the
cable
is
attached
to
the
lowest
hole
in
the
bracket
and
there
is
still
slack
in
the
cables,
the
cables
should
be
replaced
(refer
to
the
back
cover).
Re
-attach
the
side
shield.
Lower
Cable
"L"
Bracket
7