Whirlpool LEV4634JQ Installation Instructions - Page 5
Power supply cord, Direct wire
View all Whirlpool LEV4634JQ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Power supply cord Direct wire This dryer is manufactured with the cabinet-ground conductor connected to the NEUTRAL (center) of the wiring harness at the terminal block, if local codes do NOT permit this type of connection, use "Four-wire connection" instructions• GROUNDING INSTRUCTIONS_ This appliance must be grounded, In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least r_sistance for electric current. If using a power supply cord, the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. WARNING - Improper connection of the equipment grounding conductor can result in a risk of electric shock. Check with a quakged electrician or serviceman if you are in doubt as to whether the appliance is propedy grounded, Do not modify the plug provided with the appliance if it will not fit the outlet, have a proper outlet installed by a qualified electrician. If using a direct wire connection, this appliance must be connected to a grounded metal, permanent wiring system; or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance. If the house has aluminum wiring, follow the procedure below: a) Connect a section of 8 gauge solid copper wire to the connector block, b) Connect the aluminum wiring to the added section of copper wire using special connectors designed and Underwriters Laboratories Listed for joining copper to aluminum Follow the electrical connector manufacturer's recommended procedure, C) Aluminum/copper connection must conform with local codes and industry-accepted wiring practices. Fire Hazard Use a new UL approved 30 ampere power supply cord. Use a UL approved strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center terminal (silver). Ground wire (green or bare wire) must be connected to green ground connector. Connect remaining 2 supply wires to remaining 2 terminals (gold). Securely tighten all electrical connections. Failure to do so can result in death, fire, or electrical shock. 1, Disconnect the power supply. external ground screw 2, Remove hold-down tab_ t_j_/or oni'u hold cover.SCarnedw terminal block _ dc°reWn w Fire Hazard Use fO gauge solid copper wire. Use a UL approved strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center terminal (silver). Ground wire (green or bare wire) must be connected to green ground connector. Connect remaining 2 supply wires to remaining 2 terminals (gold). Securely tighten all electrical connections. Failure to do so can result in death, fire, or electrical shock. sembl 4" strain 3. AS. e 3/ relief _x "'. I d er ¢ar_Inet U.L.-I sted stra n. clamp ._... rehef (U.L. marklng sect,ons _ ,, on strain relief') into the hole below _/ ,_'C> strain relief terminal block opening, screws Tighten strain rerief screws just enough to hold the two clamp sections together. Install power supply cord/cable through the strain relieh Complete installation following instructions for your type of connection: • Four-wire (recommended method) • Three-wire (if four-wire is riot available) Four wire power supply cord must have four, No.-lO copper wires and match a : i four-wire receptacle of NEMA Type 14_ 3OR. The fourth wire (ground conductor) !_ii must be identified with a green cover and i_ii !_ the neutra conductor by a while cover. A. Remove center terminal block screw, 5. Remove appliance ground wire (green with yelJow stripes) from external ground _/_'__ connector screw. Fasten under center, silver colored terminal bJock screw. 6, Connect ground wire (green) power supply cord to external ground conductor screw. Tighten screw. 7, Connect neutral wire (white or center) of power supply cord under center screw of the terminal block. Tighten screw. 8, Connect the other wires to outer terminal block screws. Tighten screws. 9, Tighten strain relief screws. 10. Insert tab of terminal block cover into slot of the dryer rear panel, Secure_ cover with hold-down screw. Panel D Shape _ends ii of _i wires into a hook. 4. Remove center terminal block screw. 5. Remove appliance ground wire (green __" with yellow stripes) from external ground connector screw. Fasten under center, silver-colored terminal block screw. 6. Connect the ground wire (bare) of the power supply cable to the externaJ ground conductor screw. Tighten screw. 7. Place the hooked end of the ne_ wire (white or center) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hook end together, lighten screw. _. Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hook facing right). Squeeze hooked ends together. Tighten screws. 9. Nghten strain relief screws. l O, Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. {s_"% I i