Whirlpool LEV4634JQ Installation Instructions - Page 5

Power supply cord, Direct wire

Page 5 highlights

Power supply cord Direct wire This dryer is manufactured with the cabinet-ground conductor connected to the NEUTRAL (center) of the wiring harness at the terminal block, if local codes do NOT permit this type of connection, use "Four-wire connection" instructions• GROUNDING INSTRUCTIONS_ This appliance must be grounded, In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least r_sistance for electric current. If using a power supply cord, the plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. WARNING - Improper connection of the equipment grounding conductor can result in a risk of electric shock. Check with a quakged electrician or serviceman if you are in doubt as to whether the appliance is propedy grounded, Do not modify the plug provided with the appliance if it will not fit the outlet, have a proper outlet installed by a qualified electrician. If using a direct wire connection, this appliance must be connected to a grounded metal, permanent wiring system; or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance. If the house has aluminum wiring, follow the procedure below: a) Connect a section of 8 gauge solid copper wire to the connector block, b) Connect the aluminum wiring to the added section of copper wire using special connectors designed and Underwriters Laboratories Listed for joining copper to aluminum Follow the electrical connector manufacturer's recommended procedure, C) Aluminum/copper connection must conform with local codes and industry-accepted wiring practices. Fire Hazard Use a new UL approved 30 ampere power supply cord. Use a UL approved strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center terminal (silver). Ground wire (green or bare wire) must be connected to green ground connector. Connect remaining 2 supply wires to remaining 2 terminals (gold). Securely tighten all electrical connections. Failure to do so can result in death, fire, or electrical shock. 1, Disconnect the power supply. external ground screw 2, Remove hold-down tab_ t_j_/or oni'u hold cover.SCarnedw terminal block _ dc°reWn w Fire Hazard Use fO gauge solid copper wire. Use a UL approved strain relief. Disconnect power before making electrical connections. Connect neutral wire (white or center wire) to center terminal (silver). Ground wire (green or bare wire) must be connected to green ground connector. Connect remaining 2 supply wires to remaining 2 terminals (gold). Securely tighten all electrical connections. Failure to do so can result in death, fire, or electrical shock. sembl 4" strain 3. AS. e 3/ relief _x "'. I d er ¢ar_Inet U.L.-I sted stra n. clamp ._... rehef (U.L. marklng sect,ons _ ,, on strain relief') into the hole below _/ ,_'C> strain relief terminal block opening, screws Tighten strain rerief screws just enough to hold the two clamp sections together. Install power supply cord/cable through the strain relieh Complete installation following instructions for your type of connection: • Four-wire (recommended method) • Three-wire (if four-wire is riot available) Four wire power supply cord must have four, No.-lO copper wires and match a : i four-wire receptacle of NEMA Type 14_ 3OR. The fourth wire (ground conductor) !_ii must be identified with a green cover and i_ii !_ the neutra conductor by a while cover. A. Remove center terminal block screw, 5. Remove appliance ground wire (green with yelJow stripes) from external ground _/_'__ connector screw. Fasten under center, silver colored terminal bJock screw. 6, Connect ground wire (green) power supply cord to external ground conductor screw. Tighten screw. 7, Connect neutral wire (white or center) of power supply cord under center screw of the terminal block. Tighten screw. 8, Connect the other wires to outer terminal block screws. Tighten screws. 9, Tighten strain relief screws. 10. Insert tab of terminal block cover into slot of the dryer rear panel, Secure_ cover with hold-down screw. Panel D Shape _ends ii of _i wires into a hook. 4. Remove center terminal block screw. 5. Remove appliance ground wire (green __" with yellow stripes) from external ground connector screw. Fasten under center, silver-colored terminal block screw. 6. Connect the ground wire (bare) of the power supply cable to the externaJ ground conductor screw. Tighten screw. 7. Place the hooked end of the ne_ wire (white or center) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hook end together, lighten screw. _. Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hook facing right). Squeeze hooked ends together. Tighten screws. 9. Nghten strain relief screws. l O, Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. {s_"% I i

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

Power supply cord
Direct wire
Fire Hazard
This dryer
is
manufactured
with
the
cabinet-ground
conductor
connected
to
the
NEUTRAL
(center)
of
the
wiring
harness
at the terminal
block,
if local
codes do NOT
permit
this type
of
connection,
use
"Four-wire
connection"
instructions•
GROUNDING
INSTRUCTIONS_
This
appliance
must
be
grounded,
In the
event
of
malfunction
or breakdown,
grounding
will
reduce
the
risk of electric
shock
by
providing
a path
of
least
r_sistance
for electric
current.
If using
a power
supply
cord,
the
plug
must
be plugged
into
an appropriate
outlet
that
is properly
installed
and
grounded
in accordance
with
all local codes
and
ordinances.
WARNING
- Improper
connection
of the
equipment
grounding
conductor
can
result
in
a risk of electric
shock.
Check
with
a quakged
electrician
or serviceman
if you
are in doubt
as to whether
the
appliance
is
propedy
grounded,
Do not
modify
the
plug
provided
with
the
appliance
if it
will
not
fit the
outlet,
have
a
proper
outlet
installed
by a qualified
electrician.
If using
a direct
wire
connection,
this appliance
must
be
connected
to a grounded
metal,
permanent
wiring
system;
or an equipment-grounding
conductor
must
be
run with
the
circuit
conductors
and
connected
to the
equipment
grounding
terminal
or lead on the
appliance.
If the
house
has aluminum
wiring,
follow
the
procedure
below:
a) Connect
a section
of 8 gauge
solid copper
wire
to
the connector
block,
b) Connect
the
aluminum
wiring
to
the added
section
of copper
wire
using
special
connectors
designed
and
Underwriters
Laboratories
Listed
for
joining
copper
to aluminum
Follow
the
electrical
connector
manufacturer's
recommended
procedure,
C) Aluminum/copper
connection
must
conform
with
local codes
and
industry-accepted
wiring
practices.
Use a new UL
approved
30 ampere
power supply cord.
Use a UL approved strain
relief.
Disconnect
power before
making
electrical
connections.
Connect
neutral wire (white or
center
wire) to center terminal
(silver).
Ground
wire (green
or bare wire) must
be connected
to green
ground
connector.
Connect
remaining
2 supply wires to
remaining
2 terminals
(gold).
Securely tighten all electrical
connections.
Failure to do so can
result
in death,
fire, or
electrical
shock.
1,
Disconnect
the
power
supply.
external
ground
2,
Remove
hold-down
_
/
oni'u
t_j_or
screw
tab
hold
cover.SCrew
and
terminal
block
_
dc°reWw
n
Fire Hazard
Use fO gauge solid copper wire.
Use a UL approved
strain relief.
Disconnect
power
before making
electrical
connections.
Connect
neutral wire (white or center
wire) to center terminal
(silver).
Ground
wire (green
or bare wire) must
be connected
to green ground
connector.
Connect
remaining
2 supply wires to
remaining
2 terminals
(gold).
Securely tighten all electrical
connections.
Failure to do so can result in death,
fire, or electrical
shock.
sembl
4"
strain
I
d
er
3.
AS.
e
3/
relief
_x
"'.
¢
ar_Inet
U.L.-I
sted
stra
n.
clamp
....
_
rehef
(U.L.
marklng
sect,ons
_
,,
on
strain
relief')
_/
into
the
hole
below
,_'C>
strain
relief
terminal
block
opening,
screws
Tighten
strain
rerief
screws
just
enough
to
hold
the
two
clamp
sections
together.
Install
power
supply
cord/cable
through
the
strain
relieh
Complete
installation
following
instructions
for
your
type
of
connection:
Four-wire
(recommended
method)
Three-wire
(if
four-wire
is
riot available)
Four wire power
supply
cord must have
four,
No.-lO
copper
wires
and
match
a
:i
four-wire
receptacle
of NEMA Type 14-
_
3OR. The fourth
wire (ground
conductor)
!_ii must be identified
with
a green cover and
i_ii
!_
the
neutra
conductor
by a
while
cover.
A.
Remove center terminal
block screw,
5.
Remove appliance
ground
wire (green
with
yelJow stripes) from
external
ground
_/_'__
connector
screw. Fasten under center,
silver colored terminal
bJock screw.
6,
Connect
ground
wire (green)
power
supply
cord to external
ground
conductor
screw. Tighten
screw.
7,
Connect
neutral
wire (white
or center)
of power
supply
cord under center screw
of the terminal
block. Tighten
screw.
8,
Connect
the other wires to outer
terminal
block screws. Tighten
screws.
9,
Tighten
strain relief screws.
{s_"%
I
i
10.
Insert tab of terminal
block cover
into slot of the dryer
rear panel, Secure_
cover with
hold-down
screw.
Panel D
Shape
_ends
ii
of
_i
wires
into
a
hook.
4.
Remove center terminal
block screw.
Remove appliance
ground
wire (green
__"
5.
with
yellow
stripes) from
external
ground
connector
screw. Fasten
under
center,
silver-colored
terminal
block screw.
6.
Connect
the ground
wire (bare) of the
power
supply
cable to the externaJ
ground
conductor
screw.
Tighten
screw.
7.
Place the hooked end of the ne_
wire (white
or
center)
of power
supply
cable under the center screw of terminal
block (hook
facing right).
Squeeze hook
end together,
lighten
screw.
_.
Place the hooked
ends of the other
power supply
cable wires under
the
outer
terminal
block screws (hook facing
right).
Squeeze hooked ends together.
Tighten
screws.
9.
Nghten
strain relief screws.
l
O, Insert
tab
of terminal
block cover
into slot of dryer rear panel.
Secure cover
with
hold-down
screw.