Whirlpool W5CG3024XS Installation Instructions - Page 9

Make Gas Connection - regulator

Page 9 highlights

WARNING Make Gas Connection 3. Use a combination wrench and channel lock pliers to attach the flexible connector to the adapters. Check that connector is not kinked. No appliance below cooktop Wall oven installed below cooktop Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. Typical flexible connection 1. Apply pipe-joint compound made for use with Natural and LP gas to the smaller thread ends of the flexible connector adapters (see C and G in the following illustration). 2. Attach one adapter to the gas pressure regulator and the other adapter to the gas shutoff valve. Tighten both adapters. A A B C B D C E D E F G H F G I H J I K A. Manifold entrance B. Gas pressure regulator C. Use pipe-joint compound. D. Adapter (must have ½" male pipe thread) E. Flexible connector F. Adapter G. Use pipe-joint compound. H. Manual gas shutoff valve I. ½" or ¾" gas pipe A. Manifold entrance B. ³⁄₈" elbow C. Use pipe-joint compound. D. Adapter (must have ³⁄₈" male pipe thread) E. Flexible connector (pass through wall between cabinets) F. Adapter (must have ³⁄₈" male pipe thread) G. Use pipe-joint compound. H. Appliance pressure regulator (supplied) I. ½" or ¾" gas pipe J. Manual gas shutoff valve K. ½" or ¾" gas pipe 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

9
Make Gas Connection
Typical flexible connection
1.
Apply pipe-joint compound made for use with Natural and LP
gas to the smaller thread ends of the flexible connector
adapters (see C and G in the following illustration).
2.
Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
3.
Use a
¹⁵⁄₁₆
" combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
No appliance
below cooktop
Wall oven installed below cooktop
A. Manifold entrance
B. Gas pressure regulator
C. Use pipe-joint
compound.
D. Adapter (must have ½"
male pipe thread)
E. Flexible connector
F. Adapter
G. Use pipe-joint
compound.
H. Manual gas shutoff
valve
I. ½" or ¾" gas pipe
A. Manifold entrance
B.
³⁄₈
" elbow
C. Use pipe-joint compound.
D. Adapter (must have
³⁄₈
" male pipe
thread)
E. Flexible connector (pass through wall
between cabinets)
F. Adapter (must have
³⁄₈
" male pipe
thread)
G. Use pipe-joint compound.
H. Appliance pressure regulator
(supplied)
I. ½" or ¾" gas pipe
J. Manual gas shutoff valve
K. ½" or ¾" gas pipe
A
B
D
E
C
F
G
H
I
A
B
C
D
F
I
J
K
H
E
G