Whirlpool WED8300SB Use and Care Manual - Page 14

Optional exhaust installations

Page 14 highlights

An exhaust hood should cap the vent to keep rodents and insects from entering the home. Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.). Do not use an exhaust hood with a magnetic latch. Improper venting can cause moisture and lint to collect indoors, which may result in: [] Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc. [] Housecleaning problems and health problems. Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer. Other installations are possible. B A B C A. Standard rear offset exhaust installation B. Left or right side exhaust installation C. Bottom exhaust installation (not an option with pedestal installations) Alternate installations for close clearances Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer's instructions. I "_?jzz_z- i ii _s A ........ A. Dryer B. Elbow C. Wall D. Exhaust hood E. Clamps F. Rigid metal or flexible metal vent G. Vent length necessary to connect elbows H. Exhaust outlet Optional exhaust installations X ..... Xj...... A B A. Over-the-top installation (also available with one offset elbow) B. Periscope installation NOTE: The following kits for close clearance alternate installations are available for purchase. Please see the "Assistance or Service" section of this manual to order. • Over-the-Top Installation: Part Number 4396028 • Periscope Installation (For use with dryer vent to wall vent mismatch): Part Number 4396037 - 0" (0 cm) to 18" (45.72 cm) mismatch Part Number 4396011 - 18" (45.72 cm) to 29" (73.66 cm) mismatch Part Number 4396014 - 29" (73.66 cm) to 50" (127 cm) mismatch Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside. Fire Hazard Cover unused exhaust holes with the following kit: 279818 (white) Contact your local dealer. Failure to follow these instructions can result in death, fire, electrical shock, or serious injury. This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the dryer converted. 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

An exhaust
hood should cap the vent to keep rodents
and
insects
from entering
the home.
Exhaust
hood must be at least 12" (30.5 cm) from the ground
or any object that may be in the path of the exhaust
(such as
flowers,
rocks
or bushes,
snow line, etc.).
Do not use an exhaust
hood with a magnetic
latch.
Improper
venting
can
cause
moisture
and lint
to collect
indoors,
which
may result
in:
[] Moisture
damage
to woodwork,
furniture,
paint, wallpaper,
carpets,
etc.
[] Housecleaning
problems
and health problems.
Choose
your exhaust
installation
type
Recommended
exhaust
installations
Typical installations
vent the dryer from the rear of the dryer.
Other installations
are possible.
B
A
........
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible
metal vent
G. Vent length necessary
to connect
elbows
H. Exhaust outlet
Optional exhaust installations
Fire Hazard
Cover
unused
exhaust
holes
with
the following
kit:
279818 (white)
Contact
your
local
dealer.
Failure
to follow
these
instructions
can result in death,
fire, electrical
shock,
or
serious injury.
This dryer can be converted
to exhaust
out the right side, left
side, or through
the bottom.
Contact
your local dealer to have the
dryer converted.
A
B
C
A. Standard
rear offset
exhaust
installation
B. Left or right
side exhaust
installation
C. Bottom
exhaust
installation
(not an option
with pedestal
installations)
Alternate
installations
for
close
clearances
Venting systems
come in many varieties.
Select the type best for
your installation.
Two close-clearance
installations
are shown.
Refer to the manufacturer's
instructions.
I "_?jzz_z-
i
ii
_s
X
.....
Xj
......
A
B
A. Over-the-top
installation
(also available
with one
offset
elbow)
B. Periscope
installation
NOTE:
The following
kits for close clearance
alternate
installations
are available for purchase.
Please see the
"Assistance
or Service"
section of this manual to order.
Over-the-Top
Installation:
Part Number
4396028
Periscope
Installation
(For use with dryer vent to wall vent
mismatch):
Part Number
4396037
- 0" (0 cm)
to 18" (45.72 cm)
mismatch
Part Number
4396011
- 18" (45.72 cm) to 29" (73.66 cm)
mismatch
Part Number
4396014
- 29" (73.66 cm) to 50" (127 cm)
mismatch
Special
provisions
for
mobile
home
installations
The exhaust
vent must be securely
fastened
to a noncombustible
portion
of the mobile home structure
and must not terminate
beneath
the mobile
home. Terminate the exhaust
vent outside.
14