Whirlpool WET3300SQ User Instructions - Page 9

wire connection: Power supply cord, Use where local codes permit connecting cabinet-ground,

Page 9 highlights

3. Connect ground wire (green or bare) of direct wire cable to external ground conductor screw. Tighten screw. CD B 1. Loosen or remove center, silver-colored terminal block screw. 2. Connect neutral wire (white or center wire) of power supply cord to the center, silver-colored terminal screw of the terminal block. Tighten screw. C B E D A F A. External ground conductor screw B. Ground wire (green or bare) of power supply cord C. Neutral ground wire D. Center silver-colored terminal block screw E. Neutral wire (white or center) F. ¾" (1.9 cm) UL listed strain relief 4. Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws. 5. Tighten strain relief screw. 6. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. 7. You have completed your electrical connection. Now go to "Venting Requirements." 3-wire connection: Power supply cord Use where local codes permit connecting cabinet-ground conductor to neutral wire. B D E A C GF A. 3-wire receptacle (NEMA type 10-30R) B. 3-wire plug C. Neutral prong D. Spade terminals with up turned ends E 1.9 cm) UL listed strain relief F. Ring terminals G. Neutral (white or center wire) A E A. External ground conductor screw B. Neutral ground wire C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E 1.9 cm) UL listed strain relief 3. Connect the other wires to outer terminal block screws. Tighten screws. 4. Tighten strain relief screws. 5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. 6. You have completed your electrical connection. Now go to "Venting Requirements." 3-wire connection: Direct Wire Use where local codes permit connecting cabinet-ground conductor to neutral wire. Direct wire cable must have 5 ft (1.52 m) of extra length so washer/dryer can be moved if needed. Strip 3¹⁄₂" (8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2.5 cm) If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape. 1" (2.5 cm) 3¹⁄₂" (8.9 cm) When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

9
3.
Connect ground wire (green or bare) of direct wire cable to
external ground conductor screw. Tighten screw.
4.
Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
5.
Tighten strain relief screw.
6.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7.
You have completed your electrical connection. Now go to
“Venting Requirements.”
3-wire connection: Power supply cord
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
1.
Loosen or remove center, silver-colored terminal block screw.
2.
Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored terminal screw of the terminal
block. Tighten screw.
3.
Connect the other wires to outer terminal block screws.
Tighten screws.
4.
Tighten strain relief screws.
5.
Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6.
You have completed your electrical connection. Now go to
“Venting Requirements.”
3-wire connection: Direct Wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so
washer/dryer can be moved if needed.
Strip 3
¹⁄₂
" (8.9 cm) of outer covering from end of cable. Strip
insulation back 1" (2.5 cm) If using 3-wire cable with ground wire,
cut bare wire even with outer covering. Shape ends of wires into a
hook shape.
When connecting to the terminal block, place the hooked end of
the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw, as shown.
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord
C. Neutral ground wire
D. Center silver-colored terminal block screw
E. Neutral wire (white or center)
F. ¾" (1.9 cm) UL listed strain relief
A. 3-wire receptacle (NEMA type 10-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with up turned ends
E.
³⁄₄
" (1.9 cm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
A
B
C
D
E
F
A
B
D
C
E
F
G
A. External ground conductor screw
B. Neutral ground wire
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E.
³⁄₄
" (1.9 cm) UL listed strain relief
A
B
C
D
E
1"
(2.5 cm)
3
¹⁄₂
"
(8.9 cm)