Whirlpool WGD5800S Installation Instructions - Page 3

ExplosionHazard, flammable, materials - dryer

Page 3 highlights

Installation Clearances The location must be large enough to allow the dryer door to open fully. Dryer Dimensions \ 151A'' (38.74crn) 22¾" ExplosionHazard Keepflammablme aterialasnd vapors, such as gasoine, away from dryer. Place dryer at least 18 inches (48 cm) above the floor for a garage installation. Failure to do so can resumt in death, explosion, or fire. (66cm) J x You will need • A location that allows for proper exhaust installation. A gas dryer must be exhausted to the outdoors. See "Venting Requirements." • A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See "Electrical Requirements." • A sturdy floor to support the dryer and a total weight (dryer and load) of 200 Ibs (90.7 kg). The combined weight of a companion appliance should also be considered. • A level floor with a maximum slope of 1" (2.5 cm) under entire dryer. (If slope is greater than 1" [2.5 cm], install Extended Dryer Feet kit, Part No. 279810.) Clothes may not tumble properly and models with automatic sensor cycles may not operate correctly if dryer is not level. Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector. NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer. (110crn) C D A. Small Opening Side-Swing Door B. Large Opening Side-Swing Door C. Wide Opening Side-Swing Door D. Wide Opening Hamper Door *Most installations require a minimum 5V2" (14 cm) clearance behind the dryer for the exhaust vent with elbow. See "Venting Requirements." Minimum installation spacing for recessed area or closet installation The dimensions shown following are for the minimum spacing allowed. • Additional spacing should be considered for ease of installation and servicing. • Additional clearances might be required for wall, door and floor moldings.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

ExplosionHazard
Keep
flammable
materials
and
vapors,
such
as
gasoine,
away from
dryer.
Place
dryer
at
least
18 inches
(48 cm) above
the floor
for a garage
installation.
Failure
to do so can resumt in death, explosion,
or fire.
You will need
A location
that allows for proper exhaust
installation.
A gas
dryer must be exhausted
to the outdoors.
See "Venting
Requirements."
A grounded
electrical
outlet located within
2 ft (61 cm) of
either side of the dryer. See "Electrical
Requirements."
A sturdy floor to support
the dryer and a total weight
(dryer
and load) of 200 Ibs (90.7 kg). The combined
weight
of a
companion
appliance
should also be considered.
A level floor with
a maximum
slope
of 1" (2.5 cm) under entire
dryer. (If slope is greater than 1" [2.5 cm], install Extended
Dryer Feet kit, Part No. 279810.) Clothes
may not tumble
properly
and models with automatic
sensor cycles
may not
operate
correctly
if dryer is not level.
Do not operate
your dryer at temperatures
below 45°F (7°C). At
lower temperatures,
the dryer might not shut off at the end of an
automatic
cycle. Drying times
can be extended.
The dryer must not be installed or stored in an area where it will be
exposed to water and/or
weather.
Check code requirements.
Some codes limit, or do not permit,
installation
of the dryer in garages,
closets,
mobile homes, or
sleeping quarters.
Contact
your local building
inspector.
NOTE: No other fuel-burning
appliance
can be installed in the
same closet as a dryer.
Installation
Clearances
The location
must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
(66cm)
x
\
J
151A''
(38.74crn)
(110crn)
C
D
A. Small Opening
Side-Swing
Door
B. Large Opening
Side-Swing
Door
C. Wide
Opening
Side-Swing
Door
D. Wide Opening
Hamper
Door
22¾"
*Most installations
require a minimum
5V2" (14 cm) clearance
behind the dryer for the exhaust
vent with elbow. See "Venting
Requirements."
Minimum
installation
spacing
for
recessed
area or closet
installation
The dimensions
shown following
are for the minimum
spacing
allowed.
Additional
spacing
should
be considered
for ease of
installation
and servicing.
Additional
clearances
might be required for wall, door and
floor moldings.