Yamaha EF6300iSDE Owners Manual - Page 15

Hour meter, AC pilot light green, If the 240V-receptacle provides 10A, the 120V-recep

Page 15 highlights

NOTE: If you operate the generator with the voltage select switch in the 120/240V-position, the electric current will be limited for the 120V-receptacles. When you use either receptacle 1 or 2 AND recepta- 1 2 3 cle 3 at the same time, the total electric current pro- 793-7CKf vided will be equal to or even less than 22.9A. For example: If the 240V-receptacle provides 10A, the 120V-recep- tacles 1 and 2 can be used up to 12.9A each. In case the load exceeds 22.9A, the overload indicator light will turn on and the generator will stop. (At this moment the segments of the powermeter may not reach 10) If you operate the generator with the voltage select switch in the 120V-position, the receptacles 1 and 2 can supply rated current (45.8A). Hour meter 1 The hour meter 1 shows the total number of hours the generator has been run. 763-7CKf Power meter 1 The power meter 1 shows the amount of electric cur- rent used by a barmeter. The generator output is normal when the segments of the barmeter appear. NOTE: 763-7CKg When 10 segments appear, the generator has almost 1 reached its rated output. AC pilot light (green) The AC pilot light 1 comes on when the engine starts and produces power. 763-7CKc - 10 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

– 10 –
1
763-7CKf
1
763-7CKg
1
763-7CKc
Hour meter
The hour meter
1
shows the total number of hours
the generator has been run.
Power meter
The power meter
1
shows the amount of electric cur-
rent used by a barmeter.
The generator output is normal when the segments of
the barmeter appear.
NOTE:
When 10 segments appear, the generator has almost
reached its rated output.
AC pilot light (green)
The AC pilot light
1
comes on when the engine starts
and produces power.
NOTE:
If you operate the generator with the voltage select
switch in the 120/240V-position, the electric current
will be limited for the 120V-receptacles.
When you use either receptacle
1
or
2
AND recepta-
cle
3
at the same time, the total electric current pro-
vided will be equal to or even less than 22.9A.
For example:
If the 240V-receptacle provides 10A, the 120V-recep-
tacles
1
and
2
can be used up to 12.9A each.
In case the load exceeds 22.9A, the overload indicator
light will turn on and the generator will stop. (At this
moment the segments of the powermeter may not
reach 10)
If you operate the generator with the voltage select
switch in the 120V-position, the receptacles
1
and
2
can supply rated current (45.8A).
2
1
3
793-7CKf