Yamaha EF6300iSDE Owners Manual - Page 8

CONNECTION NOTES, CONNECTION, EXTENSION CORD NOTES, point for generator power and allows selection - used

Page 8 highlights

1 1 2 1 2 9 Connect the ground lead of the machine to the ground (earth) terminal 1 and connect the end to the ground electrode buried in the ground. 763-7CKa 741-7XFk AE00088 CONNECTION NOTES 9 Avoid connecting the generator to commercial power outlet. 9 Avoid connecting the generator in parallel with any other generator. 1 Correct 2 Incorrect AE00091 CONNECTION w Before the generator can be connected to a building's electrical system, a licensed electrician must install an isolation (transfer) switch in the building's main fuse box. The switch is the connection point for generator power and allows selection of generator or main line power to the building. This will prevent the generator from charging the main power line (backfeeding) when the main power supply has failed or has been turned off for line repair. Backfeeding can electrocute or injure line maintenance personnel. Also, generator and building electrical system damage can occur when normal operating power returns if unit is used without an isolation switch. AE00086 EXTENSION CORD NOTES Extension cords should be protected by a tough flexible rubber sheath (IEC 245) or the equivalent to withstand mechanical stresses. -3-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

– 3 –
1
2
1
2
741-7XFk
AE00088
CONNECTION NOTES
9
Avoid connecting the generator to commercial
power outlet.
9
Avoid connecting the generator in parallel with any
other generator.
1
Correct
2
Incorrect
AE00091
CONNECTION
w
Before the generator can be connected to a build-
ing’s electrical system, a licensed electrician must
install an isolation (transfer) switch in the build-
ing’s main fuse box. The switch is the connection
point for generator power and allows selection of
generator or main line power to the building. This
will prevent the generator from charging the main
power line (backfeeding) when the main power
supply has failed or has been turned off for line
repair. Backfeeding can electrocute or injure line
maintenance personnel. Also, generator and build-
ing electrical system damage can occur when nor-
mal operating power returns if unit is used without
an isolation switch.
AE00086
EXTENSION CORD NOTES
Extension cords should be protected by a tough flexi-
ble rubber sheath (IEC 245) or the equivalent to with-
stand mechanical stresses.
9
Connect the ground lead of the machine to the
ground (earth) terminal
1
and connect the end to
the ground electrode buried in the ground.
1
763-7CKa