Yamaha EF6300iSDE Owners Manual - Page 48
Generator won't produce power, To prevent FIRE HAZARDS
View all Yamaha EF6300iSDE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
AE00515 Generator won't produce power • Safety device (AC protector) to "Reset"····Press the AC protector to "Set". • The voltage select switch in the wrong position····Turn the voltage select switch to the right position. A ENGINE DOES NOT START B Turn the engine switch to "ON", then turn the engine switch to "START". And check if the starter motor cranks. C Cranks D Does not crank F Turn the engine switch to "START", and check if the oil warning light comes on. G Does not come on H Comes on L Turn the engine switch to "START" and check the spark plug for spark strength. (See "WARNING"). w 9 To prevent FIRE HAZARDS be sure fuel is not present in the spark plug area. 9 To prevent FIRE HAZARDS be sure to place the spark plug as far way as possible from the spark plug hole and carburetor area. 9 To prevent ELECTRIC SHOCK do not hold spark plug lead with hand while testing. M Engine does not start. N Engine starts. R Check the following 9 Fuel cock clogging 9 Air cleaner element clogging. S Clogged U Clean or Replace; Consult a Yamaha dealer. T OK V Consult a Yamaha dealer. - 43 -