Connections with an MTX/MRX system
View all Yamaha MCP1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
Connections with an MTX/MRX system Up to 16 MCP1 units can be connected to an MTX/MRX system. Use an Ethernet cable to connect the MTX/MRX's [NETWORK] port or Dante port to a PoE network switch, and use an Ethernet cable to connect the PoE network switch to the MCP1. If the network switch does not support PoE, connect a PoE injector between the network switch and the MCP1. In some cases, the PSE (PoE network switch or PoE injector) might have ports that supply power and ports that do not supply power. Connect the MCP1 to a port that supplies power. For details on how to synchronize each device, refer to "MTX-MRX Editor User Guide." Connections for a small system Maximum 100 meters MTX3 SWR2100P-5G Computer MCP1 Connections for a large system MCP1 MCP1 MCP1 MCP1 MRX7-D XMV8280-D Maximum 100 meters SWR2100P-10G SWP1-16MMF Computer MCP1 Installation Manual 9