MIDI Parameters, MIDI SYNC, Settings: Internal, External, MIDI CONTROL, Settings: Off, In, Out, In/Out
UPC - 086792626192
View all Yamaha QY100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 247 highlights
Utility Functions MIDI Parameters The parameters in the "MIDI" display all relate to MIDI control. MIDI SYNC Settings: Internal, External ;;;; When this parameter is set to "Internal" the QY100 is controlled by its own internal clock. When set to "External" the QY100 is con- trolled by a MIDI clock signal received from an external device such as a sequencer or music computer (i.e., playback of the QY100 is synchronized to that of an external sequencer or other device). Please note that the QY100 will not run on its own when this param- eter is set to "External". The QY100 can also control playback of an external MIDI sequencer when this parameter is set to "Internal". MIDI CONTROL Settings: Off, In, Out, In/Out This parameter simply turns MIDI control of the QY100 (i.e., synchronized playback) on or off. When set to "Off" the QY100 will not respond to external MIDI control. The "In" setting (MIDI input only) allows control of the QY100 from an external MIDI device, the "Out" setting (MIDI output only) allows the QY100 to control an external MIDI device, and the "In/Out" setting (MIDI input and output) allows the QY100 to both be controlled by and control an external MIDI device. 247