Yamaha XP7000 Owner's Manual - Page 14

All Models, XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual

Page 14 highlights

All Models Power Bandwidth THD+N Intermoduration Distortion Frequency Response Half Power, THD+N= 0.5 % 20 Hz-20 kHz, Half Power 60 Hz:7 kHz, 4:1, Half Power RL=8 Ω, Po=1 W, HPF=OFF 20 Hz-50 kHz Channel Separation Residual Noise Damping Factor Voltage Gain Input Sensitivity (dBu) Half Power, RL=8 Ω, 1 kHz, Att. max, input 600 Ω shunt 20 Hz-20 kHz, Att. min, (DIN AUDIO) RL=8 Ω, 1 kHz Att. max Att. max, Rated Power 8 Ω Switch Position Maximum Input Voltage Input Impedance Controls Front Panel Rear Panel Connectors Indicators Load Protection Input Output MONITOR/REMOTE POWER/STANDBY SIGNAL CLIP/LIMIT PROTECTION/TEMP Amplifier Protection Power Supply Protection Cooling Power Requirements Dimensions (W x H x D) Weight Included Accessories MIN MAX MAX MAX TYP MIN MIN 10 Hz-40 kHz 0.1 % 0.1 % 0 dB 0 dB -1 dB 70 dB MAX -70 dBu MIN TYP +4 dBu 26 dB 32 dB MIN TYP 350 (XP7000, XP5000), 200 (XP3500, XP2500, XP1000) Selectable from 32 dB or 26 dB (or +4 dBu input sensitivity) by select switch XP7000 XP5000 XP3500 XP2500 XP1000 +4 +4 +4 +4 +4 +13.7 +12.2 +10.7 +9.2 +5.2 +7.7 +6.2 +4.7 +3.2 -0.8 +22 dBu 20 kΩ (balanced), 10 kΩ (unbalanced) POWER switch (push on/push off) attenuator (31 position) x 2 MODE switch (STEREO/BRIDGED/PARALLEL) x 1 HPF switch (20 Hz/55 Hz/OFF 12 dB/oct) x 2 GAIN SELECT switch (32 dB/26 dB/+4 dBu) x 1 XLR-3-31 type/ch, Euroblock connector (balanced) /ch SPEAKON/ch, 5 way binding post x 1 Dsub 15 P x 1 x 1 (Green/Orange) x 2 (Green) x 2 (Red) x 1 (Red) x 1 (Red) heatsink temp ≥ 85 °C POWER switch on/off mute DC-fault: power supply shutdown/operation not restored automatically. (XP7000, XP5000) output relay off/restored automatically. (XP3500, XP2500, XP1000) Clip limiting : THD ≥ 0.5 % Thermal: Cuts the output (heatsink temp ≥ 90 °C) ; operation not restored automatically. VI limiter (RL ≤ 1 Ω): Limit the output. Thermal: Power supply shutdown (heatsink temp ≥ 100 °C) ; operation not restored automatically. (XP7000, XP5000). power supply shutdown (transfomer temp ≥ 130 °C) ; restored automatically. (XP3500, XP2500, XP1000) Variable-speed fan: x 1(XP3500, XP2500, XP1000), x 2 (XP7000, XP5000) Fan stop at heatsink temp < 55 °C UC: 120 V/60 Hz HB: 230 V/50 Hz A: 240 V/50 Hz 480 x 88 x 456 mm XP7000 14 kg XP5000 14 kg XP3500 15 kg XP2500 14 kg XP1000 12 kg Security cover (with a hex wrench), Owner's Manual * These specifications apply to rated power supplies of 120V, 230V and 240V. 0 dBu=0.775 Vrms, Half Power=1/2 Output Power (3 dB below rated power) Specifications and descriptions in this owner's manual are for information purposes only. Yamaha Corp. reserves the right to change or modify products or specifications at any time without prior notice. Since specifications, equipment or options may not be the same in every locale, please check with your Yamaha dealer. European models Purchaser/User Information specified in EN55103-1 and EN55103-2. Inrush Current: XP7000/5000 25A , XP3500 22A, XP2500 20A, XP1000 14A Conforms to Environments: E1, E2, E3 and E4 14 XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

14
XP7000/XP5000/XP3500/XP2500/XP1000 Owner’s Manual
* These specifications apply to rated power supplies of 120V, 230V and 240V.
0 dBu=0.775 Vrms, Half Power=1/2 Output Power (3 dB below rated power)
Specifications and descriptions in this owner’s manual are for information pur-
poses only.
Yamaha Corp. reserves the right to change or modify products or specifica-
tions at any time without prior notice. Since specifications, equipment or
options may not be the same in every locale, please check with your Yamaha
dealer.
European models
Purchaser/User Information specified in EN55103-1 and EN55103-2.
Inrush Current: XP7000/5000 25A , XP3500 22A, XP2500 20A, XP1000 14A
Conforms to Environments: E1, E2, E3 and E4
All Models
Power Bandwidth
Half Power, THD+N= 0.5 %
MIN
10 Hz-40 kHz
THD+N
20 Hz–20 kHz, Half Power
MAX
0.1 %
Intermoduration Distortion
60 Hz:7 kHz, 4:1, Half Power
MAX
0.1 %
Frequency Response
RL=8
, Po=1 W, HPF=OFF
20 Hz-50 kHz
MAX
0 dB
TYP
0 dB
MIN
-1 dB
Channel Separation
Half Power, RL=8
, 1 kHz,
Att. max, input 600
shunt
MIN
70 dB
Residual Noise
20 Hz–20 kHz, Att. min,
(DIN AUDIO)
MAX
-70 dBu
Damping Factor
RL=8
, 1 kHz
MIN
350 (XP7000, XP5000), 200 (XP3500, XP2500, XP1000)
Voltage Gain
Att. max
TYP
Selectable from 32 dB or 26 dB (or +4 dBu input sensitivity) by select switch
Input Sensitivity (dBu)
Att. max, Rated Power 8
XP7000
XP5000
XP3500
XP2500
XP1000
Switch Position
+4 dBu
+4
+4
+4
+4
+4
26 dB
+13.7
+12.2
+10.7
+9.2
+5.2
32 dB
+7.7
+6.2
+4.7
+3.2
-0.8
Maximum Input Voltage
MIN
+22 dBu
Input Impedance
TYP
20 k
(balanced), 10 k
(unbalanced)
Controls
Front Panel
POWER switch (push on/push off)
attenuator (31 position) x 2
Rear Panel
MODE switch (STEREO/BRIDGED/PARALLEL) x 1
HPF switch (20 Hz/55 Hz/OFF 12 dB/oct) x 2
GAIN SELECT switch (32 dB/26 dB/+4 dBu) x 1
Connectors
Input
XLR-3-31 type/ch, Euroblock connector (balanced) /ch
Output
SPEAKON/ch, 5 way binding post x 1
MONITOR/REMOTE
Dsub 15 P x 1
Indicators
POWER/STANDBY
x 1 (Green/Orange)
SIGNAL
x 2 (Green)
CLIP/LIMIT
x 2 (Red)
PROTECTION/TEMP
x 1 (Red)
x 1 (Red) heatsink temp
85 °C
Load Protection
POWER switch on/off mute
DC-fault:
power supply shutdown/operation not restored automatically.
(XP7000, XP5000)
output relay off/restored automatically. (XP3500, XP2500, XP1000)
Clip limiting : THD
0.5 %
Amplifier Protection
Thermal:
Cuts the output (heatsink temp
90 °C) ; operation not restored automatically.
VI limiter (RL
1
): Limit the output.
Power Supply Protection
Thermal:
Power supply shutdown (heatsink temp
100 °C) ; operation not restored auto-
matically. (XP7000, XP5000).
power supply shutdown (transfomer temp
130 °C)
; restored automatically. (XP3500, XP2500, XP1000)
Cooling
Variable-speed fan: x 1(XP3500, XP2500, XP1000), x 2 (XP7000, XP5000)
Fan stop at heatsink temp < 55 °C
Power Requirements
UC: 120 V/60 Hz
HB: 230 V/50 Hz
A: 240 V/50 Hz
Dimensions (W x H x D)
480 x 88 x 456 mm
Weight
XP7000
14 kg
XP5000
14 kg
XP3500
15 kg
XP2500
14 kg
XP1000
12 kg
Included Accessories
Security cover (with a hex wrench), Owner’s Manual