MONITOR/REMOTE PIN layout, Dimensions

Page 15 highlights

■ MONITOR/REMOTE PIN layout Pin No. 1 2 3 GND REMOTE CONTROL MONITOR Signal STANDBY MODEL ID 4 REMOTE CONTROL NC 5 NC 6 MUTE CH B 7 MUTE CH A 8 MONITOR NC 9 NC 10 PROTECTION/MUTE STATUS CH B 11 PROTECTION/MUTE STATUS CH A 12 NC 13 NC 14 OUTPUT LEVEL CH B 15 OUTPUT LEVEL CH A Description STANDBY Control: Supply 5 VDC, 5 mADC XP7000: 1.0 kΩ, XP5000: 1.2 kΩ, XP3500: 1.5 kΩ, XP2500: 1.8 kΩ, XP1000: 2.2 kΩ (Impedance to GND) MUTE On Control: Connect the pin to GND (max. 1mA flows) MUTE Off Control: Open the pin (+5V applied) Protection/Mute On: +5 VDC, Zo=270 Ω Protection/Mute Off: 0 VDC, Zo=High XP7000, XP5000, XP3500, XP2500, XP1000 +4dBu (-27.2 dB of Speaker Output Level) at 100 W/8Ω, RL=7.5 kΩ, Zo=300 Ω ■ Dimensions Unit: mm 30 456 374.5 5.5 46 30 362 30 480 88 XP7000/XP5000/XP3500/XP2500/XP1000 Owner's Manual 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

XP7000/XP5000/XP3500/XP2500/XP1000 Owner’s Manual
15
MONITOR/REMOTE PIN layout
Dimensions
Unit: mm
Pin No.
Signal
Description
1
GND
2
REMOTE CONTROL
STANDBY
STANDBY Control:
Supply 5 VDC, 5 mADC
3
MONITOR
MODEL ID
XP7000: 1.0 k
, XP5000:
1.2 k
, XP3500:
1.5 k
,
XP2500:
1.8 k
, XP1000:
2.2 k
(Impedance to GND)
4
REMOTE CONTROL
NC
5
NC
6
MUTE CH B
MUTE On Control: Connect the pin to GND (max. 1mA flows)
MUTE Off Control: Open the pin (+5V applied)
7
MUTE CH A
8
MONITOR
NC
9
NC
10
PROTECTION/MUTE STATUS CH B
Protection/Mute On: +5 VDC, Zo=270
Protection/Mute Off: 0 VDC, Zo=High
11
PROTECTION/MUTE STATUS CH A
12
NC
13
NC
14
OUTPUT LEVEL CH B
XP7000, XP5000, XP3500, XP2500, XP1000
+4dBu (-27.2 dB of Speaker Output Level) at 100 W/8
, RL=7.5 k
, Zo=300
15
OUTPUT LEVEL CH A
88
456
480
362
30
30
5.5
374.5
30
46