Zenith SL-5511-BZ User Guide - Page 2

Installation - replacement for sensor

Page 2 highlights

INSTALLATION ❒ To insert the new bulb, push the bulb into the right socket so the bulb fits completely into the left For easy installation, select an existing light with a wall socket. switch for replacement. ❒ Check that the bulb is seated properly. For best performance, locate the fixture about 8 ft. (2.4 m) ❒ Close the glass cover. Replace screw. above the ground. CAUTION: The sensor must be mounted below the Wire the Light Control lamp housing for wall installations. ❒ Turn the power to the lighting circuit off at the fuse or circuit breaker box. ❒ Remove the existing light fixture. ❒ Strip about 5/8" insulation from the existing junction ❒ Drill out the holes if needed box wiring. to mount the backplate to the ❒ Route the light control's wires through the large junction box. hole in the gasket. ❒ Twist the junction box wires and fixture wires together as shown. Secure with wire connectors. CAUTION to avoid fire or burn hazards: • Allow fixture to cool before touching. The bulb and fixture operate at high temperatures. • Keep fixture at least 2" (5 cm) from combustible materials. Do not aim at objects closer than 3 feet (1 m). • Re-lamp with type T 150W (or less) halogen 120 VAC lamp only. Black to Black White to White For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. ❒ Rotate the sensor head towards the clamp screw joint. Controls Junction box ground wire to green ground wire on fixture. Cover Plate Gasket Clamp Screw ❒ Then rotate the sensor head counterclockwise 180° so the controls face down. Mount the Light Control ❒ Align the light control cover plate and cover plate gasket and the junction box. Insert and tighten the mounting screws. ❒ If not installed on a weatherproof box or if an adaptor plate is used, caulk the wall plate and mounting surface with silicone weather sealant. Controls If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done. Bulb Installation and Relamping ❒ When relamping, turn power off and let the fixture cool. ❒ Remove the screw that holds the glass cover shut. Remove the old bulb by pushing the bulb towards the right until the left side of the bulb is clear of the left socket.  RIGHT WRONG The halogen light must be mounted horizontally (+/- 4°). 595-5574-06

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

2
595-5574-06
Drill out the holes if needed
to mount the backplate to the
junction box.
INSTALLATION
For easy installation, select an existing light with a wall
switch for replacement.
For best performance, locate the fixture about 8 ft. (2.4 m)
above the ground.
CAUTION: The sensor must be mounted below the
lamp housing for wall installations.
Turn the power to the lighting circuit off at the
fuse or circuit breaker box.
Remove the existing light fixture.
Strip about 5/8" insulation from the existing junction
box wiring.
Route the light control’s wires through the large
hole in the gasket.
Twist the junction box wires and fixture wires together
as shown. Secure with wire connectors.
Align the light control cover plate and cover plate
gasket and the junction box. Insert and tighten the
mounting screws.
If not installed on a weatherproof box or if an adaptor
plate is used,
caulk the wall plate and mounting
surface
with silicone weather sealant.
M
OUNT
THE
L
IGHT
C
ONTROL
Cover Plate
Gasket
The halogen light must be
mounted horizontally (+/- 4°).
RIGHT
WRONG
B
ULB
I
NSTALLATION
AND
R
ELAMPING
When relamping,
turn power off
and let the fixture
cool.
Remove the screw that holds the glass cover shut.
Remove the old bulb by pushing the bulb towards
the right until the left side of the bulb is clear of the
left socket.
CAUTION to avoid fire or burn hazards:
• Allow fixture to cool before touching. The bulb
and fixture operate at high temperatures.
• Keep fixture at least 2" (5 cm) from combustible
materials. Do not aim at objects closer than 3 feet
(1 m).
• Re-lamp with type T 150W (or less) halogen 120
VAC lamp only.
For under eave installation, the sensor head must
be rotated
as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
Black
to
Black
White
to
White
Rotate the sensor head to-
wards the clamp screw joint.
Then rotate the sensor
head counterclockwise
180° so the controls face
down.
Controls
Junction box ground wire to
green ground wire on fixture.
W
IRE
THE
L
IGHT
C
ONTROL
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
Clamp Screw
Controls
To insert the new bulb, push the bulb into the right
socket so the bulb fits completely into the left
socket.
Check that the bulb is seated properly.
Close the glass cover. Replace screw.