Asus Pro WS WRX90E-SAGE SE IPMI EXPANSION CARD Users Manual English - Page 108

A.1 IPMITool help commands, Command, Description

Page 108 highlights

A.1 IPMITool help commands Command raw i2c spd lan chassis power event mc sdr sensor fru gendev sel pef sol tsol isol user channel session sunoem kontronoem picmg fwum firewall exec set hpm ekanalyzer ime vita lan6 Description Send a RAW IPMI request and print response. Send an I2C Master Write-Read command and print response. Print SPD info from remote I2C device. Configure LAN Channels. Get chassis status and set power state. Shortcut to chassis power commands. Send pre-defined events to MC. Management Controller status and global enables. Print Sensor Data Repository entries and readings. Print detailed sensor information. Print built-in FRU and scan SDR for FRU locators. Read/Write Device associated with Generic Device locators sdr. Print System Event Log (SEL). Configure Platform Event Filtering (PEF). Configure and connect IPMIv2.0 Serial-over-LAN. Configure and connect with Tyan IPMIv1.5 Serial-over-LAN. Configure IPMIv1.5 Serial-over-LAN. Configure Management Controller users. Configure Management Controller channels. Print session information. OEM Commands for Sun servers. OEM Commands for Kontron devices. Run a PICMG/ATCA extended cmd. Update IPMC using Kontron OEM Firmware Update Manager. Configure Firmware Firewall. Run list of commands from file. Set runtime variable for shell and exec. Update HPM components using PICMG HPM.1 file. Run FRU-Ekeying analyzer using FRU files. Update Intel Manageability Engine Firmware. Run a VITA 46.11 extended cmd. Configure IPv6 LAN Channels. A-2 Appendix

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122

A-2
Appendix
A.1
IPMITool help commands
Command
Description
raw
Send a RAW IPMI request and print response.
i2c
Send an I2C Master Write-Read command and print response.
spd
Print SPD info from remote I2C device.
lan
Configure LAN Channels.
chassis
Get chassis status and set power state.
power
Shortcut to chassis power commands.
event
Send pre-defined events to MC.
mc
Management Controller status and global enables.
sdr
Print Sensor Data Repository entries and readings.
sensor
Print detailed sensor information.
fru
Print built-in FRU and scan SDR for FRU locators.
gendev
Read/Write Device associated with Generic Device locators sdr.
sel
Print System Event Log (SEL).
pef
Configure Platform Event Filtering (PEF).
sol
Configure and connect IPMIv2.0 Serial-over-LAN.
tsol
Configure and connect with Tyan IPMIv1.5 Serial-over-LAN.
isol
Configure IPMIv1.5 Serial-over-LAN.
user
Configure Management Controller users.
channel
Configure Management Controller channels.
session
Print session information.
sunoem
OEM Commands for Sun servers.
kontronoem
OEM Commands for Kontron devices.
picmg
Run a PICMG/ATCA extended cmd.
fwum
Update IPMC using Kontron OEM Firmware Update Manager.
firewall
Configure Firmware Firewall.
exec
Run list of commands from file.
set
Set runtime variable for shell and exec.
hpm
Update HPM components using PICMG HPM.1 file.
ekanalyzer
Run FRU-Ekeying analyzer using FRU files.
ime
Update Intel Manageability Engine Firmware.
vita
Run a VITA 46.11 extended cmd.
lan6
Configure IPv6 LAN Channels.