Brother International BAS-311F-L Instruction Manual - English - Page 62

New BAS-311F-L X -110 mm

Page 62 highlights

10.DIPSWITCH DIP switch A SW No. When ON A-5 After sewing is completed, work clamp does not automatically rise (only in split mode) A-6 Clamping force output is produced (Inner clamping device available as an option) A-7 Single-pedal operation using the starting switch; when the starting switch is pressed, the work clamp drops, and when it is released, sewing starts. A-8 Thread breakage detector device is activated (available as an option) DIP switch B SW No. When ON B-1 Single split mode activated B-2 BAS-311F-L: The sewing area in the X direction is extended to 230 mm from 220 mm.* B-3 Thread is not trimmed after an emergency stop. B-4 Needle cooler output is produced. B-5 When a rotating-type thread breakage detector device is used, detection precision is increased from 8 to 14. When a fiber-type thread breakage detector device is used, detection precision is increased from 5 to 10. B-6 Fiber-type thread breakage detector device is ON, and DIP switch A - 8 is ON (available as an option) When using a 3-stage pedal B-7 If DIP switch A -2 is ON at the same time, the presser foot will drop at the same time that both work clamps drop. B-8 Feeding speed is switched to high speed. * If using the work clamp and sewing data for the older BAS-311EL model, set DIP switch B -2 ON. The BAS-311 L-type has a different length for the sewing area in the X direction (X=220 mm). Old BAS-311EL X -100 mm +120 mm New BAS-311F-L X -110 mm +110 mm Note The break of the sewing pattern is apt to occur in the extended sewing area. BAS-311F-0, 311F-L, 326F-0 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81

10.DIPSWITCH
BAS-311F-0, 311F-L, 326F-0
55
DIP switch
A
SW No.
When ON
A
-5
After sewing is completed, work clamp does not automatically rise (only in split mode)
A
-6
Clamping force output is produced (Inner clamping device available as an option)
A
-7
Single-pedal operation using the starting switch; when the starting switch is pressed, the work clamp
drops, and when it is released, sewing starts.
A
-8
Thread breakage detector device is activated (available as an option)
DIP switch
B
SW No.
When ON
B
-1
Single split mode activated
B
-2
BAS-311F-L: The sewing area in the X direction is extended to 230 mm from 220 mm.*
B
-3
Thread is not trimmed after an emergency stop.
B
-4
Needle cooler output is produced.
B
-5
When a rotating-type thread breakage detector device is used, detection precision is increased from 8 to 14.
When a fiber-type thread breakage detector device is used, detection precision is increased from 5 to 10.
B
-6
Fiber-type thread breakage detector device is ON, and DIP switch
A
- 8 is ON (available as an option)
B
-7
When using a 3-stage pedal
If DIP switch
A
-2 is ON at the same time, the presser foot will drop at the same time that both work clamps
drop.
B
-8
Feeding speed is switched to high speed.
* <BAS-311F-L only>
If using the work clamp and sewing data for the older BAS-311EL model, set DIP switch
B
-2 ON.
The BAS-311 L-type has a different length for the sewing area in the X direction (X=220 mm).
Old
BAS-311EL X -100 mm
+120 mm
New BAS-311F-L X -110 mm
+110 mm
Note
The break of the sewing pattern is apt to occur in the extended sewing area.