Brother International BAS-341E Programmer Instruction Manual - English - Page 209
Example 3 of extended option output, Signal for peripheral equipment, Timing chart
View all Brother International BAS-341E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 209 highlights
Chapter 4 Extended Option Output Example 3 of extended option output Signal for peripheral equipment When the machine is connected to an external programmable controller, this is a sequence example for issuing timing signals. Option output 4 Option output 5 Option output 6 READY Signal ready for sewing END Signal of sewing completion THBK Signal of detecting thread breakage Timing chart 3&"%: &/% 5)#, TFD Movement of start point Movement of start point when embroidering is completed. Machine returned to home position or change of P. No. Start of step back or machine returned to home position, change of P. No. Detection of thread breakage Program setting value Output No. Operation Output condition setting Condition No. Description ON 2 Movement of start point Timer 1 [mS] 0 4 1 Movement of start point OFF 0 17 Change of P. No. 5 ON 2 Movement of start point 0 ON 16 Detection of thread breakage 0 6 8 Start of step back OFF 0 77 Output 4 OFF Timer 2 [mS] 0 Enable condition O Condition No. Description Disable condition X Condition No. Description - - - - 0 100 6 Embroidering completion 1 Machine returns to home position. 0 - - - - 0 208 1SPHSBNNFS