Brother International LK3-B438E MKII Instruction Manual - English - Page 25

. Operating procedure, Program No., X-scale, Speed rpm, Factory default, Variable range

Page 25 highlights

5 . OPERATION 5-2 . Operating procedure Preparation Turn on the power switch. (The POWER indicator q will illuminate and the pro gram number will flash in the display window !4.) Program No. X-scale (%) Factory default Variable range 00 * 01 - 49 100 20 - 200 Y-scale (%) 100 20 - 200 Speed (rpm) 2000 1,000 - 2,500 * For checking the origin points for X and Y feed 5-2-1 . Setting the program number Determine the appropriate program from the program list which is given on pp. 3 - 5. 1 Press the SELECT switch y until the PROGRAM NO. indicator illuminates. P PROGRAM NO. X-SCALE y Y-SCALE 2 Press the DISPLAY SET switches !2 until the desired program number is flashing in the display window. 3 Depress the foot switch to the second step. * The display will stop flashing and illuminates steadily, and the feed mechanism will move to the sewing start position. 1st step 2nd step SPEED COUNTER SELECT This completes the setting of the pro- !2 gram number. 5-2-2 . Setting the X-scale and Y-scale 1 Press the SELECT switch y until the X-scale or Y-scale indicator illuminates. P PROGRAM NO. 2 Press the DISPLAY SET switches !2 until the desired scale setting is flashing in the display window. (The setting is displayed as a per- centage.) X-SCALE y Y-SCALE SPEED !2 COUNTER SELECT 3 Depress the foot switch to the second step. * The display will stop flashing and illuminates steadily, and the feed mechanism will move to the sewing start position. 1st step 2nd step This completes the setting of the X-scale or Y-scale. 5-2-3 . Setting the sewing speed 1 Press the SELECT switch y until the SPEED indicator illuminates. 2 Press the DISPLAY SET switches !2 until the desired speed setting is flashing in the display window. NOTE: Be sure to check the sewing pattern (refer to page 20) after setting has been completed to make sure that the needle drops down into the hole of the button. P PROGRAM NO. X-SCALE y Y-SCALE SPEED COUNTER SELECT !2 19 LK3-B438E Mark II

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

LK3-B438E Mark II
19
5-2 . Operating procedure
Program No.
X-scale (%)
Y-scale (%)
Speed (rpm)
Factory default
00 *
100
100
2000
Variable range
01 - 49
20 - 200
20 - 200
1,000 - 2,500
SELECT
PROGRAM NO.
COUNTER
X-SCALE
Y-SCALE
SPEED
P
SELECT
PROGRAM NO.
COUNTER
X-SCALE
Y-SCALE
SPEED
P
SELECT
PROGRAM NO.
COUNTER
X-SCALE
Y-SCALE
SPEED
P
Press the SELECT switch
y
until the PROGRAM NO. in-
dicator illuminates.
Press the DISPLAY SET
switches
!2
until the desired
program number is flashing
in the display window.
Depress the foot switch to
the second step.
*
The display will stop flashing
and illuminates steadily, and
the feed mechanism will move
to the sewing start position.
This completes the setting of the pro-
gram number.
1
2
3
Press the SELECT switch
y
until the X-scale or Y-scale
indicator illuminates.
Press the DISPLAY SET
switches
!2
until
the
de-
sired scale setting is flash-
ing in the display window.
(The setting is displayed as a per-
centage.)
Depress the foot switch to
the second step.
* The display will stop flashing
and illuminates steadily, and
the feed mechanism will move
to the sewing start position.
1
2
3
Press the SELECT switch
y
until the SPEED indicator il-
luminates.
Press the DISPLAY SET
switches
!2
until
the
de-
sired speed setting is flash-
ing in the display window.
1
2
This completes the setting of the X-scale
or Y-scale.
y
y
y
!
2
!
2
1st step
2nd step
Preparation
Turn on the power switch.
(The POWER indicator
q
will illuminate and the pro
gram number will flash in the display window
!4
.)
* For checking the origin points for X and Y feed
5-2-1 . Setting the program number
Determine the appropriate program from the program list which is given on pp. 3 - 5.
5-2-2 . Setting the X-scale and Y-scale
5-2-3 . Setting the sewing speed
1st step
2nd step
NOTE:
Be sure to check the sewing pattern
(refer to page 20) after setting has
been completed to make sure that
the needle drops down into the hole
of the button.
5 . OPERATION
!