Clifford AvantGuard 5 Owners Guide - Page 45
Adjusting Primary Zone
View all Clifford AvantGuard 5 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
Read the following instructions thoroughly for a full understanding of how to properly adjust this sensor. 1. Disarm system 2. Transmit Channel 16 (Press 1-time) 3-times then z The LED will turn on and the siren will chirp 1-time. z Primary (full trigger) zone adjustment has now been entered. z Primary zone can now be adjusted. 3. Adjusting Primary Zone z Press of the remote control to increase sensitivity. z Press of the remote control to decrease sensitivity. z The sensor Primary zone can be tested at any time during adjustment and will generate 1 siren chirp each time the zone is activated. 4. Press to adjust Warn-Away zone z Siren chirps 1 time. z Warn-away Zone adjustment has now been entered. z Warn-away Zone can now be adjusted. 5. Adjust Warn-away Zone z Press to increase sensitivity. z Press to decrease sensitivity. z The sensor Warn-away zone can be tested at any time during adjustment and will generate 1 siren chirp each time the zone is activated. 42