D-Link DSN-626 User Manual - Page 136
Configuration, > Set SSD Caching, Enable, Select Disks
View all D-Link DSN-626 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 136 highlights
C * P = I * S *D * T So we can estimate the warm up time, at least. T = (C * P) / (I * S * D) D-Link Document - User Manual The real case may be longer than the estimate time. Here we take an example of the following. I: 250 IOPS (Random IOPS per HDD) S: 64KB (Web service) D: 16 HDDs C: 480GB (1 SSD) P: 2 (Populate-on-read threshold) Warm up time T = (480GB * 2) / (250 * 64KB * 16) = 3932.16 seconds = 65.536 minutes Configuration Take an example of enabling SSD caching. 1. After creating a virtual disk, click▼ -> Set SSD Caching of the selected virtual disk. 2. Check Enable box. 3. Select the policy by drop down menu. 4. Click Select Disks button, and then check the SSDs which are provided for SSD caching. 5. Click OK button to enable SSD caching. Copyright@2014 D-Link System, Inc. All Rights Reserved. 136