D-Link DSN-626 User Manual - Page 81
SES, Select UPS Type
View all D-Link DSN-626 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
D-Link Document - User Manual Options UPS Type Shutdown Battery Level (%) Shutdown Delay (Seconds) Shutdown UPS IP Address (This option is only visible when the UPS type is Smart-UPS (SNMP).) Community (This option is only visible when the UPS type is Smart-UPS (SNMP).) Status Battery level (%) Description Select UPS Type: None: No UPS or other vendors. Smart-UPS (Serial port): APC UPS with serial port. Smart-UPS (SNMP): APC UPS with network function. Megatec-UPS: Megatec UPS. When below the setting level, the system will shut down. Setting level to "0" will disable UPS. If power failure occurs and system power cannot recover after the time setting, the system will shut down. Setting delay to "0" will disable the function. Select ON, when the power is off, the UPS will shut down by itself after the system shutdown is successful. After the power comes back on, UPS will start working and notify system to boot up. OFF will not. The IP address of the network UPS. The SNMP community of the network UPS. The status of UPS: Detecting... Running Unable to detect UPS Communication lost UPS reboot in progress UPS shutdown in progress Batteries failed. Please change them NOW! Current power percentage of battery level. The system will shut down when either the Shutdown battery level (%) or Shutdown Delay (Seconds) reaches the set condition. Users should set these values carefully. SES The SES (SCSI Enclosure Services, one of the enclosure management standards) tab is used to enable or disable the management of SES. Copyright@2014 D-Link System, Inc. All Rights Reserved. 81