D-Link DSN-626 User Manual - Page 81

SES, Select UPS Type

Page 81 highlights

D-Link Document - User Manual Options UPS Type Shutdown Battery Level (%) Shutdown Delay (Seconds) Shutdown UPS IP Address (This option is only visible when the UPS type is Smart-UPS (SNMP).) Community (This option is only visible when the UPS type is Smart-UPS (SNMP).) Status Battery level (%) Description Select UPS Type:  None: No UPS or other vendors.  Smart-UPS (Serial port): APC UPS with serial port.  Smart-UPS (SNMP): APC UPS with network function.  Megatec-UPS: Megatec UPS. When below the setting level, the system will shut down. Setting level to "0" will disable UPS. If power failure occurs and system power cannot recover after the time setting, the system will shut down. Setting delay to "0" will disable the function. Select ON, when the power is off, the UPS will shut down by itself after the system shutdown is successful. After the power comes back on, UPS will start working and notify system to boot up. OFF will not. The IP address of the network UPS. The SNMP community of the network UPS. The status of UPS:  Detecting...  Running  Unable to detect UPS  Communication lost  UPS reboot in progress  UPS shutdown in progress  Batteries failed. Please change them NOW! Current power percentage of battery level. The system will shut down when either the Shutdown battery level (%) or Shutdown Delay (Seconds) reaches the set condition. Users should set these values carefully. SES The SES (SCSI Enclosure Services, one of the enclosure management standards) tab is used to enable or disable the management of SES. Copyright@2014 D-Link System, Inc. All Rights Reserved. 81

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155

D-Link Document – User Manual
Options
Description
UPS Type
Select UPS Type:
None: No UPS or other vendors.
Smart-UPS (Serial port): APC UPS with serial port.
Smart-UPS (SNMP): APC UPS with network function.
Megatec-UPS: Megatec UPS.
Shutdown
Battery Level (%)
When below the setting level, the system will shut down. Setting level to
“0” will disable UPS.
Shutdown Delay
(Seconds)
If power failure occurs and system power cannot recover after the time
setting, the system will shut down. Setting delay to “0” will disable the
function.
Shutdown UPS
Select ON, when the power is off, the UPS will shut down by itself after
the system shutdown is successful. After the power comes back on, UPS
will start working and notify system to boot up. OFF will not.
IP Address
(This option is
only visible when
the UPS type is
Smart-UPS
(SNMP).)
The IP address of the network UPS.
Community
(This option is
only visible when
the UPS type is
Smart-UPS
(SNMP).)
The SNMP community of the network UPS.
Status
The status of UPS:
Detecting…
Running
Unable to detect UPS
Communication lost
UPS reboot in progress
UPS shutdown in progress
Batteries failed. Please change them NOW!
Battery level (%)
Current power percentage of battery level.
The system will shut down when either the
Shutdown battery level (%)
or
Shutdown Delay
(Seconds)
reaches the set condition. Users should set these values carefully.
SES
The
SES
(SCSI Enclosure Services, one of the enclosure management standards) tab is used to
enable or disable the management of SES.
81