Installing a DC Power Supply Module

Page 20 highlights

DXS-3400 Series Lite Layer 3 Stackable 10GbE Managed Switch Hardware Installation Guide Figure 2-7 Installing a DC Power Supply Module Figure 2-8 Connecting a DC Battery to the DC Power Supply Module The DC power and AC power of the device will back each other up immediately when one of the power sources fails. Before connecting the DC power cable to the DC power input socket on the Switch, the DC power cable must be properly connected to DC source at your facility by a qualified licensed electrician. The DC power cable's wire gauge must be 18 AWG. Connect the DC power cable to a DC main circuit breaker rated no greater than 15 A. If you are installing a DC-powered switch, you must ground the chassis before connecting the Switch to the DC power source, using the following instructions:  Use a minimum of 18 AWG stranded copper wire. The wire should be long enough to reach from the Switch to the facility ground point.  Torque screwdriver with a 1/4-inch flat blade.  Ground additional hardware appropriately to the earth ground connection at your site. 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

DXS-3400 Series Lite Layer 3 Stackable 10GbE Managed Switch Hardware Installation Guide
20
Figure 2-7 Installing a DC Power Supply Module
Figure 2-8 Connecting a DC Battery to the DC Power Supply Module
The DC power and AC power of the device will back each other up immediately when one of the power sources fails.
Before connecting the DC power cable to the DC power input socket on the Switch, the DC power cable must be
properly connected to DC source at your facility by a qualified
licensed electrician. The DC power cable’s wire
gauge
must be 18 AWG. Connect the DC power cable to a DC main circuit breaker rated no greater than 15 A.
If you are installing a DC-powered switch, you must ground the chassis before connecting the Switch to the DC power
source, using the following instructions:
Use a minimum of 18 AWG stranded copper wire. The wire should be long enough to reach from the Switch to
the facility ground point.
Torque screwdriver with a 1/4-inch flat blade.