Dacor CM24 Installation Instruction - Automatic Coffee System - Page 10

To install the cabinet glides

Page 10 highlights

Installation Instructions Installing the Cabinet Glides The cabinet glides mount to the inside of the cabinet. The glides on the coffee system slide into the cabinet glides. The glides system allows the coffee system to slide in and out of the cabinet for loading the coffee bins and for maintenance. To install the cabinet glides: • Determine the number of shims required to mount the cabinet glide assemblies according to the chart and diagrams below. The appliance is supplied with six 1/16" (1mm) metal shims. Use the shims to position the fixing angles so that they are properly spaced. The appliance will not slide in and out of the cabinet properly if the fixing angles are not properly spaced. • Put the two cabinet glide assemblies, and shims if necessary, as shown on the inside surfaces of the cabinet. Position them 3 1/2" (90mm) from the front edge of the cutout opening. • Insert the screws in the holes of the glides without tightening them completely. • Make sure the outside distance between the fixing angles is 22 1/8" (562mm) and that the glides are level. Change the number of shims or adjust the fixing angles as necessary. 4" (100mm) Cabinet Back Cutout for Air Circulation Cutout Width 22 1/8" (562mm) 22 3/16" (564mm) 22 1/4" (566mm) 22 3/8" (568mm) Number of Metal Shims Required 0 2 total (1 on each side) 4 total (2 on each side) 6 total (3 on each side) 4" X 12" (100mm X 300mm) Min. Cabinet Back Cutout for Air Circulation 3/4" (19mm) Min. Side Walls Cabinet Rear 3 9/16" (9.0cm) 3 1/2" (8.9cm) Cabinet Front 22 1/8" (562mm) Nom. 18" (45.7cm) Fixing Angle Cabinet Glide Cabinet Glide Installation IMPORTANT: Make sure that glides are level. • Tighten all of the screws. • Make sure that the power cord and water feed line can be fed freely through the back wall. • In order to avoid overheating the coffee system, make an opening of at least 3 15/16" (100mm) at the back of the cabinet to allow air to circulate. Cabinet Glide Asssembly Shim Side Wall Cabinet Base Cabinet Glide Assembly and Shims 

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

¸
Put the two cabinet glide assemblies, and shims if
necessary, as shown on the inside surfaces of the
cabinet. Position them 3 1/2” (90mm) from the front
edge of the cutout opening.
Insert the screws in the holes of the glides without
tightening them completely.
Make sure the outside distance between the fixing
angles is 22 1/8” (562mm) and that the glides are
level. Change the number of shims or adjust the
fixing angles as necessary.
IMPORTANT: Make sure that glides are level.
Tighten all of the screws.
Make sure that the power cord and water feed line
can be fed freely through the back wall.
In order to avoid overheating the coffee system,
make an opening of at least 3 15/16” (100mm) at the
back of the cabinet to allow air to circulate.
The cabinet glides mount to the inside of the cabinet.
The glides on the coffee system slide into the cabinet
glides. The glides system allows the coffee system to
slide in and out of the cabinet for loading the coffee
bins and for maintenance.
To install the cabinet glides:
Determine the number of shims required to mount the
cabinet glide assemblies according to the chart and
diagrams below. The appliance is supplied with six
1/16” (1mm) metal shims. Use the shims to position
the fixing angles so that they are properly spaced.
The appliance will not slide in and out of the cabinet
properly if the fixing angles are not properly spaced.
I
NSTALLATION
I
NSTRUCTIONS
22 1/8” (562mm) Nom.
3/4” (19mm)
Min. Side Walls
4” X 12” (100mm X 300mm) Min.
Cabinet Back Cutout for
Air Circulation
Side Wall
Cabinet Base
Shim
Fixing Angle
Cabinet
Glide
Cabinet
Glide
Asssembly
Cutout Width
Number of Metal Shims Required
22 1/8” (562mm)
0
22 3/16” (564mm)
2 total (1 on each side)
22 1/4” (566mm)
4 total (2 on each side)
22 3/8” (568mm)
6 total (3 on each side)
Cabinet Front
Cabinet Rear
4” (100mm)
Cabinet Back Cutout for
Air Circulation
3 1/2”
(8.9cm)
18”
(45.7cm)
3 9/16”
(9.0cm)
Cabinet Glide Installation
I
NSTALLING
THE
C
ABINET
G
LIDES
Cabinet Glide Assembly and Shims