Dacor CM24 Installation Instruction - Automatic Coffee System - Page 7

Nominal Cutout Specifications

Page 7 highlights

Planning the Installation Nominal Cutout Specifications Ventilation opening in back of cabinet 4" X 12" Min. (100mm X 300mm) Overhanging cabinet Veritical distance to overhanging cabinet Vertical Distance CM24T 14" Minimum CM24P 6" Minimum 14" Minimum 22" (559mm) Min. distance to floor of room: 1" (25.4mm) Max. recommended distance to floor of room: 36" (914mm) Coffee maker pulled out from cabinet During normal operation, the user must have access to the top of the unit. The user needs to be able to pour coffee into the coffee bins on top and, on model CM24T, be able to remove the water tank for filling and cleaning. Install the coffee maker low enough so that the user can reach the top of the unit easily when it is slid out of the cabinet. warning Electric Shock Hazard: Due to steam and spillage during normal use, DO NOT install this appliance above or below any other appliance. All tolerances are + 1/16", - 0" unless otherwise stated. 24" (610mm) 3/4" (19mm) Level Support Platform Optimal Water and Electrical Supply Location 3/4" (19mm) Min. Side Walls 17 7/8" (454mm) 8"" (203mm) 1" (26mm) 6" (152mm) min. to room floor 22 1/8" - 22 3/8" (562mm - 568mm) 1" Min. (26mm) Steam Barrier (provided) 20 3/4" (527mm) 1/8" (3mm) 22 3/16" (564mm) 3/4" (19mm) Min. Side Walls Screw 8 places (provided) 1" Min. (26mm) 

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

µ
P
LANNING
THE
I
NSTALLATION
17 7/8”
(454mm)
1” (26mm)
Screw 8 places
(provided)
3/4” (19mm)
Level Support Platform
24”
(610mm)
Steam Barrier
(provided)
Optimal Water
and Electrical
Supply Location
20 3/4”
(527mm)
1/8”
(3mm)
22 3/16”
(564mm)
1” Min.
(26mm)
1” Min. (26mm)
3/4” (19mm)
Min. Side Walls
22 1/8” - 22 3/8”
(562mm - 568mm)
8””
(203mm)
6” (152mm) min.
to room floor
3/4” (19mm)
Min. Side Walls
N
OMINAL
C
UTOUT
S
PECIFICATIONS
Coffee maker pulled
out from cabinet
Overhanging
cabinet
Veritical distance
to overhanging cabinet
22” (559mm)
Min. distance to
floor of room: 1” (25.4mm)
Max. recommended
distance to floor of room:
36” (914mm)
Ventilation opening in
back of cabinet
4” X 12” Min.
(100mm X 300mm)
During normal operation, the user must
have access to the top of the unit. The
user needs to be able to pour coffee into
the coffee bins on top and, on model
CM24T, be able to remove the water tank
for filling and cleaning. Install the coffee
maker low enough so that the user can
reach the top of the unit easily when it is
slid out of the cabinet.
Vertical Distance
CM24T
14” Minimum
CM24P
6” Minimum
14” Minimum
All tolerances are + 1/16”, - 0” unless
otherwise stated.
WARNING
Electric Shock Hazard
: Due to steam and
spillage during normal use,
DO NOT
install
this appliance above or below any other
appliance.