Dell PowerStore 5200T EMC PowerStore Release Notes for PowerStore OS Version 3 - Page 24
The Inband Migration Tool IMT Copy, Import External Storage in PowerStore
View all Dell PowerStore 5200T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Issue ID MDT-431882 MDT-430742 MDT-356233 MDT-295614 MDT-252560 MDT-430310 MDT-418998 Functional Area Description Workaround/Resolution Import Import Import Import Import Install or Upgrade Install or Upgrade When importing data from PowerMax/VMAX remote systems to PowerStore, not all Storage Groups of the remote system may be discovered in PowerStore when the volume count in PowerMax/VMAX exceeds 2000. When importing data from PowerMax/VMAX remote systems to PowerStore, the discovery of storage resources on a PowerMax/VMAX remote system may fail if the remote systems have active Symmetrix Remote Data Facility (SRDF) sessions. The Inband Migration Tool (IMT) "Copy Progress Percentage" and "Estimated Completion Time" displays an incorrect progress of 0% on the File Imports tab of the Import External Storage page in PowerStore Manager. Performing a non-disruptive import using a Windows host plug-in may fail on a PowerStore cluster with multiple storage networks. If multiple storage networks are configured, all the iSCSI portals are returned on discovery, but iSCSI portal filtering is not supported by PowerStore. Import of a volume failed with the error "Import failed because the mirror service could not be enabled on the Destination volume". A PowerStore software upgrade may fail when an appliance contains the maximum number of volumes. The Quick Start Guide states that there are two Mini-SAS HD cables included with the PowerStore Base Enclosure. As of May 13, 2022, the Mini-SAS HD cables are no longer provided with the PowerStore Base Enclosure. None. If any of the PowerMax/VMAX arrays are in SRDF relation with active SRDF sessions, import data from one array when both the SRDF source and target PowerMax/VMAX arrays are imported to the same PowerStore cluster. Add either the source or the target PowerMax/VMAX array to PowerStore cluster first. Then, complete the import and delete the first PowerMax/VMAX array before attempting to import data from the second array. Contact your service provider if you need assistance. Use the REST API command /file_import_session/{id} to view the current_operation_progress_percentage and estimated_completion_timestamp for a file import session. If needed, contact your service provider for assistance. Use one of the following workarounds: - If possible, remove all the storage networks except for the storage network on which the Windows host resides. - Perform an agentless import. Run the verify operation on the remote system to recover data connections. Once the remote system verify operation completes successfully, try the import operation again. Contact your service provider for assistance to work around this issue before upgrading the PowerStore software. The expansion enclosure cables are provided with the 25x2.5 SAS expansion enclosure. 24 Known Issues