Environmental Specifications, AC Adapter
View all Epson DS-320 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 107 highlights
Rated input voltage Rated input current Power consumption DC 5 V 3A Operating: 8 W (approximately) Ready mode: 2.5 W (approximately) Sleep mode: 0.9 W (approximately) Power off mode: 0.3 W or less AC Adapter AC adapter model Rated input current Rated input frequency Rated output voltage Rated output current 100 to 240 V model: A491H 220 to 240 V model: A492E 0.6 A 50 to 60 Hz DC 5 V 3A Parent topic: Technical Specifications Environmental Specifications Temperature Humidity (non-condensing) Operating conditions Operating: 41 to 95 °F (5 to 35 °C) Storage: -13 to 140 °F (-25 to 60 °C) Operating: 15 to 80% RH Storage: 15 to 85% RH Ordinary office or home conditions Note: Avoid operating the scanner in direct sunlight, near a strong light source, or in extremely dusty conditions. Parent topic: Technical Specifications 107