Fluke 287/FVF Product Manual - Page 61
Recording Measurement Data
View all Fluke 287/FVF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
287/289 Users Manual softkeys labeled Prev and Next to select an item for deletion. Next, press the softkey labeled Delete. A message asking to confirm the deletion will appear before anything is deleted from memory. Recording Measurement Data The Meter's record feature collects measurement information over a user-specified duration. This collection of information is called a recording session. A recording session is made up of one or more measurement records. Each record contains measurement summary information covering the duration of the record. Each record contains the minimum, maximum, and average value detected over the record's duration. In addition to measurement values, time stamps are also captured and saved with each record. The time stamps consist of the record start time, the time the maximum value was detected, the time the minimum value was detected, and the record end time. Some of a records data can be viewed through the Meter's Viewing Trend Data function. Viewing all the data that makes up a record can only be viewed on a PC running FlukeView Forms software. There are two measurement record types that are captured during a recording session: interval and event. An interval record covers a user-specified interval. An event record has a duration determined by the activity of the measured signal and can interrupt an interval record. Even if an interval record is interrupted, a record will end and a new interval record will begin when the scheduled interval time expires. 52 Event records are triggered by the measured signal varying more than an adjustable percentage of the value measured at the start of the record. This adjustable percent is called the Event Threshold for recording. In addition to the values and time stamps mentioned above, an event record also stores whether the signal was stable or unstable during the event record duration. To be classified as stable, the measured signal's value must stay within the selected percentage of the start value for at least one second. Measured signals that exceed the percentage threshold in less than one second are classified as unstable. See the "Setting the Event Threshold Value" section later in this manual. Note For temperature measurements, the AutoHold threshold is a percent of 100 degrees. The default AutoHold threshold is 4% of 100 degrees, or 4 degrees Celsius or Fahrenheit. A record ends when one of the following occurs: • The start of a new interval record. • A range overload, causing the Meter to change range. • A non-ranging overload, when in manual range or the highest range. • The measured value changes more than 4 % of the measured value at the start of the record. • The recording session terminates. A recording session termination can be caused by one of the following: MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664