Fujitsu MBA3073NC Product Manual - Page 30
Table 2.3, Environmental/power requirements continued, Error rate - replacement
View all Fujitsu MBA3073NC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Table 2.3 Environmental/power requirements (continued) Item Regulation Ready (average) Power +5V DC requirement (*5) Peak operating current Maximum (peak) DC (*6) Peak operating current DC (reference) (*6) Ripple (+5 V, +12 V) MBA3300NC MBA3300NP Specification MBA3147NC MBA3147NP ± 5 % 0.5 A MBA3073NC MBA3073NP 1.5 A 0.79 A 250 mVp-p or less (*7) (*1) For detail condition, see Section 4.1. (*2) Vibration applied to the drive is measured at near the mounting screw hole on the frame as much as possible. (*3) At random seek write/read and default on retry setting with log sweep vibration. (*4) At power-off state after installation Vibration displacement should be less than 2.5 mm. (*5) Input voltages are specified at the HDD connector side during HDD Idle state. (*6) Operating currents are values under random W/R operation of full partition at about 220 IOPS. (*7) High frequency noise (over 20 MHz) is less than 100 mVp-p. 2.1.4 Error rate Errors detected during initialization and replaced by alternate block assignments are not included in the error rate. Data blocks to be accessed should be distributed over the disk equally. (1) Unrecoverable error rate Errors which cannot be recovered within 63 retries and ECC correction should not exceed 10 per 1016 bits read. (2) Positioning error rate Positioning errors which can be recovered by one retry should be 10 or less per 108 seeks. 26 Downloaded from www.Manualslib.com manuals search engine C141-E270