Installation Instructions, CONNECTING AN ELECTRIC DRYER cont., WARNING
UPC - 084691191261
View all GE DCVH485EKMS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
Installation Instructions CONNECTING AN ELECTRIC DRYER (cont.) CONNECTING DRYER USING 3-WIRE CONNECTION Ground strap Bracket 1. Turn off the circuit breaker(s) (30 amp) or remove the dryer's circuit fuse at the electrical box. 2. Be sure the dryer cord is unplugged from the wall receptacle. 3. Remove the power cord cover located at the upper back. 4. Bring the power cord through the bracket. 5. Connect power cord as follows: A. Connect the 2 hot lines to the outer screws of the terminal block (marked L1 and L2). B. Connect the neutral (white) line to the center of the terminal block (marked N). 6. Be sure ground strap is connected to green ground screw on cabinet rear. Tighten all terminal block screws (3) completely. 7. Reinstall the cover. WARNING - NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK. 16