GE GUD27GSSJWW Installation Instructions - Page 2
Installation Instructions - manual
View all GE GUD27GSSJWW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Installation Instructions INSTALLATION REQUIREMENTS LOCATION 7KLVDSSOLDQFHPXVWEHLQVWDOOHGRQ¿UPÀRRULQJWRPLQLPL]H YLEUDWLRQ GXULQJ VSLQ F\FOH &RQFUHWH ÀRRULQJ LV EHVW EXW ZRRGEDVHLVVXȻFLHQW SURYLGHGÀRRUVXSSRUWPHHWV)+$ standards. This appliance should not be installed on rugs or exposed to weather. PLUMBING WATER PRESSURE - Must be 20 psi minimum to 120 psi maximum. WATER TEMPERATURE - Household water heater should be VHWWRGHOLYHUZDWHUDWWR WR& ,17+( WASHER when hot wash is selected. 6+872))9$/9(6%RWKKRWDQGFROGVKXWRȺYDOYHVIDXFHWV should be supplied. DRAIN - Water may be drained into standpipe or set tub. Discharge height MUST NOT BE LESS THAN 30 INCHES, DQG QR PRUH WKDQ IHHW DERYH WKH EDVH RI WKH ZDVKHU Standpipe must be 1-1/2 inches minimum inside diameter and must be open to atmosphere. ELECTRICAL REQUIREMENTS CAUTION: Before plugging in washer, read the following electrical requirements. CAUTION: For personal safety, do not use an extension cord or adapter plug with this appliance. Do not, under any circumstances, cut or remove the third grounding prong from the power cord. Follow national electrical codes and ordinances. This appliance must be supplied with the voltage and frequency indicated on the rating plate (located at the top of the dryer front panel), and connected to an individual, properly grounded branch circuit, protected by a 15- or 20amp circuit breaker or time-delay fuse. If the electric supply provided does not meet the above requirements, call a licensed electrician. Step 1 Verify Your Gas Installation (see section 2). Step 2 Prepare the Area and Exhaust for Installation of appliance (see section 1). Step 3 Check and Insure the Existing External Exhaust is Clean (see section 1) and Meets Attached ,QVWDOODWLRQ6SHFL¿FDWLRQVVHHVHFWLRQ Step 4 Remove the Foam Shipping Pads (see section 1). Step 5 Move the appliance to the Desired Location. 6WHS/HYHO\RXUDSSOLDQFHVHHVHFWLRQ Step 7 Connect the Gas Supply (see section 3) and check for leaks (see section 4). Step 8 Connect the External Exhaust (see section 7). Step 9 Connect to plumbing facilities (see section 11). Step 10 Connect the Power Supply (see section 5). Step 11 Check the Operation of the Power Supply, Gas Connections, and Venting. Step 12 Place the Owners Manual and the Installation Instructions in a Location Where They Will Be Noticed By the Owner. For Alcove or Closet Installation see section 13. For Bathroom or Bedroom Installation see section 14. For Mobile or Manufactured Home see section 12. ADJUSTING FOR ELEVATION • Gas clothes dryers input ratings are based on sea level operation and need not be adjusted for operation at or below 2000 ft. elevation. For operation at elevations above 2000 ft., input ratings should be reduced at a rate of 4 percent for each 1000 ft. above sea level. • Installation must conform to local codes and ordinances or, in their absence with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1. 2