Gigabyte GA-X48-DS4 Manual - Page 24

NB_FAN North Bridge Fan Header, 4/5 CPU_FAN/SYS_FAN1/SYS_FAN2/PWR_FAN Fan Headers - cpu support

Page 24 highlights

3/4/5) CPU_FAN/SYS_FAN1/SYS_FAN2/PWR_FAN (Fan Headers) The motherboard has a 4-pin CPU fan header (CPU_FAN), a 3-pin (SYS_FAN1) and a 4-pin (SYS_FAN2) system fan headers, and a 3-pin power fan header (PWR_FAN). Each fan header supplies a +12V power voltage and possesses a foolproof insertion design. When connecting a fan cable, be sure to connect it in the correct orientation. Most fans are designed with color-coded power connector wires. A red power connector wire indicates a positive connection and requires a +12V voltage. The black connector wire is the ground wire. The motherboard supports CPU fan speed control, which requires the use of a CPU fan with fan speed control design. For optimum heat dissipation, it is recommended that a system fan be installed inside the chassis. CPU_FAN: Pin No. Definition 1 GND 1 2 +12V / Speed Control CPU_FAN 3 Sense 4 Speed Control SYS_FAN2: Pin No. Definition 1 1 GND SYS_FAN2 2 Speed Control 3 Sense 4 +5V SYS_FAN1/PWR_FAN: Pin No. Definition 11 1 GND SYS_FAN1 6) NB_FAN (North Bridge Fan Header) PWR_FAN 2 +12V 3 Sense Connect the North Bridge fan cable to this header. The fan header has a foolproof insertion design. When connecting a fan cable, be sure to connect it in the correct orientation. Most fans are designed with color-coded power connector wires. A red power connector wire indicates a positive connection and requires a +12V voltage. The black connector wire is the ground wire. 1 Pin No. Definition 1 GND 2 +12V 3 NC • Be sure to connect fan cables to the fan headers to prevent your CPU, North Bridge and system from overheating. Overheating may result in damage to the CPU/North Bridge or the system may hang. • These fan headers are not configuration jumper blocks. Do not place a jumper cap on the headers. GA-X48-DS4 Motherboard - 24 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

GA-X48-DS4 Motherboard
- 24 -
6)
NB_FAN (North Bridge Fan Header)
Connect the North Bridge fan cable to this header. The fan header has a foolproof insertion design.
When connecting a fan cable, be sure to connect it in the correct orientation. Most fans are designed
with color-coded power connector wires. A red power connector wire indicates a positive connec-
tion and requires a +12V voltage. The black connector wire is the ground wire.
1
Be sure to connect fan cables to the fan headers to prevent your CPU, North Bridge and
system from overheating. Overheating may result in damage to the CPU/North Bridge or
the system may hang.
These fan headers are not configuration jumper blocks. Do not place a jumper cap on the
headers.
3/4/5) CPU_FAN/SYS_FAN1/SYS_FAN2/PWR_FAN (Fan Headers)
The motherboard has a 4-pin CPU fan header (CPU_FAN), a 3-pin (SYS_FAN1) and a 4-pin
(SYS_FAN2) system fan headers, and a 3-pin power fan header (PWR_FAN). Each fan header
supplies a +12V power voltage and possesses a foolproof insertion design. When connecting a fan
cable, be sure to connect it in the correct orientation. Most fans are designed with color-coded
power connector wires. A red power connector wire indicates a positive connection and requires
a +12V voltage. The black connector wire is the ground wire. The motherboard supports CPU fan
speed control, which requires the use of a CPU fan with fan speed control design. For optimum
heat dissipation, it is recommended that a system fan be installed inside the chassis.
Pin No.
Definition
1
GND
2
+12V
3
NC
Pin No.
Definition
1
GND
2
+12V
3
Sense
SYS_FAN1/PWR_FAN:
1
PWR_FAN
1
SYS_FAN1
1
CPU_FAN
SYS_FAN2
1
Pin No.
Definition
1
GND
2
+12V / Speed Control
3
Sense
4
Speed Control
CPU_FAN:
Pin No.
Definition
1
GND
2
Speed Control
3
Sense
4
+5V
SYS_FAN2: