Haier AB092FCBHA User Manual

Haier AB092FCBHA Manual

Haier AB092FCBHA manual content summary:

  • Haier AB092FCBHA | User Manual - Page 1
    Air Conditioner AB092FCBHA AB142FCBHA AB182FCBHA Contents Before use Cautions 1-3 Diagram 4 Safety precautions 5-7 Maintenance Maintenance 8 Seasonal cessation 9 Trouble No:0010571442 B l Please read this operation manual carefully before using the appliance. l Keep this manual in a safe place.
  • Haier AB092FCBHA | User Manual - Page 2
    waste materials collecting centers and waste paper disposal services nearest to your house. Safety Instructions and Warnings Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly
  • Haier AB092FCBHA | User Manual - Page 3
    . Inadequate repairs may result in a major source of danger for the user of the air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the
  • Haier AB092FCBHA | User Manual - Page 4
    humidity is high, water droplets may condense at the air outlet of the air conditioner during cooling or dehumidifying. Airflow speed change If the automatic mode is set for cooling, the airflow speed will decrease gradually as the room temperature approaches the set point.
  • Haier AB092FCBHA | User Manual - Page 5
    . When the defrosting mode is activated, the outdoor unit and indoor unit cease operation. After completion of defrosting, the air conditioner will resume operation. Note When the air conditioner is used for heating, heat from outside the room is transferred to inside. In such a case, the heating
  • Haier AB092FCBHA | User Manual - Page 6
    instructions should be available at hand any time for convenient reference. This operation manual should always be attached to this appliance even if the appliance is transferred. Installation ! WARNING Authorization This appliance sufficient refrigerant. For personal safety and trouble-free
  • Haier AB092FCBHA | User Manual - Page 7
    inlet or outlet must be avoided when the unit is in operation to prevent injury and equipment damage. Operation of the air conditioner must cease, manual power switch must be turned off and an after-sales agent must be contacted if abnormal circumstances occur, such as burning, to prevent fire and
  • Haier AB092FCBHA | User Manual - Page 8
    not directly exposed to the airflow coverage as plants may wither.* Never place water containers on the appliance to prevent electric hazards caused by accidental spillage. Never clean the air conditioner with water to prevent electric hazards. Never place or use inflammable spray on or close to
  • Haier AB092FCBHA | User Manual - Page 9
    Maintenance Cleaning Unplug the appliance Do not touch the appliance Do not clean the appliance with with wet hands. hot water or chemical solutions. Remove the air intake screen Hold the air intake screen with one hand, and push the screen inward with the other hand to release four tabs from
  • Haier AB092FCBHA | User Manual - Page 10
    and leave it running for about 6 hours. Turn the air conditioner off and disconnect it from the power source. Clean the filter, the indoor unit and outdoor unit before applying covers. Advance maintenance Verify that there is no blockage at the air intake and output openings of the indoor unit and
  • Haier AB092FCBHA | User Manual - Page 11
    Trouble shooting The following are not problems. Water gurgling sound Pop sound Strange odor Mists from indoor unit Ha Ha A slight sound similar to water gurgling can be produced when the appliance is turned on and off, or the compressor started or ceased during operation period of the appliance.
  • Haier AB092FCBHA | User Manual - Page 12
    for a certain period of time to dissipate remaining heat in the appliance after it is turned off. Please undertake following tests before contacting authorized after sales service for technical assistance. The air conditioner does not operate Is the switch connected to the power resource? ON
  • Haier AB092FCBHA | User Manual - Page 13
    circumstances occur after inspection has been carried out for the items listed above, turn off the air conditioner and contact authorized aftersales service agent: Regular break of fuse and circuit. Water leaks during cooling or dehumidifying process. Abnormal operation status or strange sound. 12
  • Haier AB092FCBHA | User Manual - Page 14
    instructions should be strictly followed for appliance operation. l Installation must be carried out in accordance with the requirements listed hereunder. l When the air conditioner air conditioner should be properly operated in accordance with the instructions in this manual. Operation Instructions
  • Haier AB092FCBHA | User Manual - Page 15
    there is no refrigerant leak, which may turn into toxic gas when it is heated by a radiator or stove. Do not install the air conditioner close to an inflammable gas source. Drainage duct should be arranged and installed in accordance with the instructions in the operation manual and measures should
  • Haier AB092FCBHA | User Manual - Page 16
    Leak tester and soap solution 12. Steel tape 13. Scraper and file 14.Refrigeration oil(polyol ester) Code A B C Material 1-side adhesive tape 2-sided adhesive duct dime- Liquid pipe nsions Gas pipe Copper tube option AB092FCBHA O 6.35(1/4") O 9.52(3/8") AB142FCBHA O 6.35(1/4") O12.7(1/2")
  • Haier AB092FCBHA | User Manual - Page 17
    by the manufacture for the air conditioner installation. Code 1 Remote Controller Figure 2 Battery 3 wire Binder 4 Insulation 5 Sleave Quantity 1 30X100mm 35X120mm 2 6 1 1 Code Figure 6 Ring 7 Rubber Pad Quantity 1 4 8 Putty 1 9 10 Refrigeration Oil Plastic Clamp (POE Oil
  • Haier AB092FCBHA | User Manual - Page 18
    and connection to the heat pump l Favorable for airflow spread l Accessible to power source with required space around the appliance l Free from TV sets, radio, cordless appliance and at least 1 meter away from the light l Convenient for receiving signals from remote controller fixed on the wall
  • Haier AB092FCBHA | User Manual - Page 19
    and radio H *0.31m II. Preparation for installation 1.5m Airflow Air intake Airflow outlet inlet outlet 1.5m Over2.5m (1) Location of installed.Refer to the figure above for specific dimensions. Tubes for refrigerant and water drainage and electrical wires for remote controller, the fun
  • Haier AB092FCBHA | User Manual - Page 20
    (Installation illustration) Ensure that the hanger rods are properly set to the slot of the pedestals on the indoor unit. Tighten the nuts with washers on both sides of the pedestal. (2) Installation of ceilings. Refer to the information on previous page or consult an architect or carpenter for
  • Haier AB092FCBHA | User Manual - Page 21
    Installation of indoor unit IV. Installation of water drain 1. Installation of water drainpipes l Diameter of water drainpipes should exceed or be equal to that of connecting pipe. (Polyethylene pipe: inside diameter 25mm and outside diameter 32mm.) l Water drainpipe should be short with a gradient
  • Haier AB092FCBHA | User Manual - Page 22
    for top panel installation 1. Top panel is installed as shown in the figure. 2. Incorrect installation of the top panel may result in air leaks and fluctuation, as well as failure of signal transmission and display. Synchronous motor Liquid intake pipe Water drainpipe Backflow pipe 21
  • Haier AB092FCBHA | User Manual - Page 23
    Optimized radii of bends Spanner l Insulation to be applied on all gaseous pipes Nut l Flared section free from cracks (4) Pipe connection Process Apply refrigeration oil on the end of the pipe to be connected and on the flared section. Align the pipes to be connected and tighten the nut. (
  • Haier AB092FCBHA | User Manual - Page 24
    wires. 1(L) Wiring of indoor unit Wiring diagram of loop terminals l Remove air intake screen and take out the front wires. l Connect the wires as wire connections. l Properly apply capping clips on the wires. l Replace the air intake screen. l Do not link the connecting and signal wire with the
  • Haier AB092FCBHA | User Manual - Page 25
  • Haier AB092FCBHA | User Manual - Page 26
  • Haier AB092FCBHA | User Manual - Page 27
  • Haier AB092FCBHA | User Manual - Page 28
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

l
Please read this operation manual carefully before using the appliance.
l
Keep this manual in a safe place.
AB092FCBHA
AB142FCBHA
AB182FCBHA
No:0010571442
Contents
Before use
Cautions
**************************1-3
Diagram
***************************4
Safety precautions
*********************5-7
Maintenance
Maintenance
************************ 8
Trouble shooting
*********************10-12
Precautions
*************************13
Tests and trial operation
*******************24
Built-in Household Cassette Air Conditioner
B
Seasonal cessation
********************* 9
Instroduction
***********************14-16
Procedures
*************************17
Indoor unit installation
Installation of indoor unit
*****************18-21
Pipe connection
********************** 22
Electric wiring
***********************23