Haier AB092FCBHA User Manual - Page 24

Electric wiring

Page 24 highlights

Electric wiring Process of wire connections 1. Loop terminal After removing the screw, fix the wire ring on the screw, reinsert the screw into the block terminal and then tighten the screw. 2. Straight terminal After loosening the screw, inset the wire end into the block terminal and then tighten the screw. Slightly pull the wire to see if it is tightly fixed. 3. Wire capping After completion of connection, capping clips must be applied on the external sleeve of the wires. 1(L) Wiring of indoor unit Wiring diagram of loop terminals l Remove air intake screen and take out the front wires. l Connect the wires as specified in the above methods and diagrams for indoor unit and wire connections. l Properly apply capping clips on the wires. l Replace the air intake screen. l Do not link the connecting and signal wire with the same cable, a snug space must be maintained between connecting and signal wires. l Shield of the signal wire should be spot grounded. Block terminal Capping clip Wiring diagram: Block terminals N L C1 C2 for indoor unit W B Y/G R R Block terminals N L for outdoor unit W B (different outdoor Y/G unit have different block terminals) C1 C2 RR 23 NOTE* W:WHITE B*BLACK Y/G:YELLOW/GREEN R:RED

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Process of wire connections
1. Loop terminal
After removing the screw, fix the wire ring on the screw, reinsert the screw into the
block terminal and then tighten the screw.
2. Straight terminal
After loosening the screw, inset the wire end into the block terminal and then tighten
the screw. Slightly pull the wire to see if it is tightly fixed.
3. Wire capping
After completion of connection, capping clips must be
applied on the external sleeve of the wires.
Wiring diagram:
W:
WHITE
B*BLACK
Y/G:YELLOW/GREEN
R:RED
NOTE*
Wiring of indoor unit
l
Remove air intake screen and take out the front wires.
l
Connect the wires as specified in the above
methods and diagrams for indoor unit and
wire con-
nections.
l
Properly apply capping clips on the wires.
l
Replace the air intake screen.
l
Do not link the connecting and signal wire with the
same cable, a snug space must be maintained
between connecting and signal wires.
l
Shield of the signal wire should be spot grounded.
Block terminal
Capping clip
Wiring diagram of loop terminals
1(L)
Block terminals
for indoor unit
Block terminals
for outdoor unit
(different outdoor
unit have different block terminals)
N
L
C1 C2
W
B Y/G
R
R
N
L
C1
W
B
Y/G
R
R
C2
23
Electric wiring