Haier AB092FCBHA User Manual - Page 24
Electric wiring
View all Haier AB092FCBHA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Electric wiring Process of wire connections 1. Loop terminal After removing the screw, fix the wire ring on the screw, reinsert the screw into the block terminal and then tighten the screw. 2. Straight terminal After loosening the screw, inset the wire end into the block terminal and then tighten the screw. Slightly pull the wire to see if it is tightly fixed. 3. Wire capping After completion of connection, capping clips must be applied on the external sleeve of the wires. 1(L) Wiring of indoor unit Wiring diagram of loop terminals l Remove air intake screen and take out the front wires. l Connect the wires as specified in the above methods and diagrams for indoor unit and wire connections. l Properly apply capping clips on the wires. l Replace the air intake screen. l Do not link the connecting and signal wire with the same cable, a snug space must be maintained between connecting and signal wires. l Shield of the signal wire should be spot grounded. Block terminal Capping clip Wiring diagram: Block terminals N L C1 C2 for indoor unit W B Y/G R R Block terminals N L for outdoor unit W B (different outdoor Y/G unit have different block terminals) C1 C2 RR 23 NOTE* W:WHITE B*BLACK Y/G:YELLOW/GREEN R:RED