Page 28 highlights

pH Tank Low The pH Tank Low alarm will sound when the chemical being fed falls below the optional optical level sensor in the tank. First check the chemical level. If the level is above the sensor, check the sensor for obstruction or scaling. ORP Out Of Range Oxidation Reduction Potential is a measure of the oxidizing capacity present in water. Unlike a DPD chlorine reading, which can only differentiate between free available chlorine and the less effective combined chlorine, ORP provides an accurate measure of water quality regardless of pH, TDS, cyanuric acid, or non- chlorine oxidizers. The proper ORP range for swimming pools and spas is between 650 and 800 mV, with any value above 650 resulting in healthy water quality. ORP Overfeed The ORP Overfeed timeout occurs when the CAT 3500 has been feeding chemicals for a time greater than the selected maximum feed time and has not reached its set point. A properly selected Overfeed timeout prevents the unit from continuing to feed chemicals when the chemical supply has been diminished or a chemical feeder has become clogged or broken. First, check the chemical supply and chemical feeder. If both are in order check the Overfeed timer setting as it may need to be increased to keep up with chemical demand. ORP Tank Low The ORP Tank Low alarm will sound when the chemical being fed falls below the chemical level in the tank. First check the chemical level. If the level is above the sensor, check the sensor for obstruction or calcification. No Flow The CAT 3500 is equipped with a flow sensor to prevent the controller from feeding chemicals in the absence of proper recirculation. First check the filtration system to ensure that it is running and that water is moving through the flow cell. If water is flowing and the alarm is still sounding check flow sensor for obstruction. When using the optional Digital Flow Sensor, the digital flow alarm setting can be entered in gallons-per-minute to send a No Flow alarm when the filters require cleaning or backwashing. Technical Specifications Enclosure Type 7" x 7" x 2.3" Glass Filled Polycarbonate Enclosure Properties NEMA Type 1, 4, 4X, 6, 12, 13 Flame Resistance UL94-5V (UL 746 C 5) Display 2 x 20 Character Vacuum Fluorescent Front Panel UV Protected Lexan Membrane Switch Key Type Embossed with Stainless Tactile Domes 27 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
27
pH Tank Low
The pH Tank Low alarm will sound when the chemical being fed falls below the optional optical
level sensor in the tank. First check the chemical level. If the level is above the sensor, check the
sensor for obstruction or scaling.
ORP Out Of Range
Oxidation Reduction Potential is a measure of the oxidizing capacity present in water. Unlike a DPD
chlorine reading, which can only differentiate between free available chlorine and the less effective
combined chlorine, ORP provides an accurate measure of water quality regardless of pH, TDS,
cyanuric acid, or non- chlorine oxidizers. The proper ORP range for swimming pools and spas is
between 650 and 800 mV, with any value above 650 resulting in healthy water quality.
ORP Overfeed
The ORP Overfeed timeout occurs when the CAT 3500 has been feeding chemicals for a time
greater than the selected maximum feed time and has not reached its set point. A properly selected
Overfeed timeout prevents the unit from continuing to feed chemicals when the chemical supply
has been diminished or a chemical feeder has become clogged or broken. First, check the chemi-
cal supply and chemical feeder. If both are in order check the Overfeed timer setting as it may need
to be increased to keep up with chemical demand.
ORP Tank Low
The ORP Tank Low alarm will sound when the chemical being fed falls below the chemical level
in the tank. First check the chemical level. If the level is above the sensor, check the sensor for
obstruction or calcification.
No Flow
The CAT 3500 is equipped with a flow sensor to prevent the controller from feeding chemicals in
the absence of proper recirculation. First check the filtration system to ensure that it is running and
that water is moving through the flow cell. If water is flowing and the alarm is still sounding check
flow sensor for obstruction.
When using the optional Digital Flow Sensor, the digital flow alarm setting can be entered in
gallons-per-minute to send a No Flow alarm when the filters require cleaning or backwashing.
Technical Specifications
Enclosure Type
7” x 7” x 2.3” Glass Filled Polycarbonate
Enclosure Properties
NEMA Type 1, 4, 4X, 6, 12, 13
Flame Resistance
UL94-5V (UL 746 C 5)
Display
2 x 20 Character Vacuum Fluorescent
Front Panel
UV Protected Lexan Membrane Switch
Key Type
Embossed with Stainless Tactile Domes