Hayward OnCommand® Model: ALL MODELS Installation - Page 15

VSC Pump Address Setting, Temperature Sensors

Page 15 highlights

Hayward Variable Speed Filter Pump: Refer to the diagram below for proper low voltage communication wiring between the OnCommand and the Hayward Tristar Variable Speed Control (VSC). Connect screw terminals "1" to "1", "2" to "2", etc. VSC 1234 4 GRN 3 2 1 YEL BLK RED RED BLK YEL GRN Use four conductor cable (typically phone cable) for communications connection between the VSC and the OnCommand. The maximum wiring distance is 500 feet (160 meters). Note that the terminals on both the VSC interface board and the OnCommand main board are numbered. The terminal connections should be matched between both terminal blocks (connect 1 to 1, 2 to 2, etc.). The communications cable should be routed through the knockout hole on the left side of the VSC enclosure, and a watertight fitting should be used to keep water and debris out of the opening. The communications cable should also be routed away from the OnCommand and VSC power connections if possible. VSC Pump Address Setting The VSC address must be set to 001 when using the VSC with the OnCommand. Refer to the TriStar Pump Owner's Manual (IS3220VSC) and Hayward document IS3220VSCAQLL for specific instructions on setting the pump address. Temperature Sensors The OnCommand utilizes 10K ohm thermistor type sensors. Three sensors (water temperature, air temperature and solar temperature) are included. If the OnCommand is being used to control a solar heating system, the solar sensor is required. The sensors are provided with a 15 ft. cable. If a longer cable is required, contact the Goldline Technical Support department for information on suitable cable types and splices. See page 2 and the diagram below for installation information. POOL/SPA SENSOR AIR SENSOR SOLAR SENSOR optional 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Hayward Variable Speed Filter Pump:
Refer to the diagram below for proper low voltage communication
wiring between the OnCommand and the Hayward Tristar Variable Speed Control (VSC).
Use four conductor cable (typically phone cable) for communications connection between the VSC and the
OnCommand. The maximum wiring distance is 500 feet (160 meters).
Note that the terminals on both the VSC
interface board and the OnCommand main board are numbered.
The terminal connections should be matched
between both terminal blocks (connect 1 to 1, 2 to 2, etc.).
The communications cable should be routed through
the knockout hole on the left side of the VSC enclosure, and a watertight fitting should be used to keep water and
debris out of the opening.
The communications cable should also be routed away from the OnCommand and VSC
power connections if possible.
VSC Pump Address Setting
The VSC address must be set to 001 when using the VSC with the OnCommand.
Refer to the TriStar Pump
Owner’s Manual (IS3220VSC) and Hayward document IS3220VSCAQLL for specific instructions on setting
the pump address.
Temperature Sensors
The OnCommand utilizes 10K ohm thermistor type sensors.
Three sensors (water temperature, air temperature
and solar temperature) are included.
If the OnCommand is being used to control a solar heating system, the solar
sensor is required.
The sensors are provided with a 15 ft. cable.
If a longer cable is required, contact the Goldline
Technical Support department for information on suitable cable types and splices.
See page 2 and the diagram
below for installation information.
12
4
4
2
2
3
3
1
1
GRN
YEL
BLK
RED
GRN
YEL
BLK
RED
VSC
Connect screw terminals
“1” to “1”, “2” to “2”, etc.
AIR
SENSOR
SOLAR
SENSOR
POOL/SPA
SENSOR
optional