Heater Setpoints in Groups The OnCommand can be programmed to use alternate heater setpoints (conventional and/or solar) while running a group command. This allows the heater to be set to a higher or lower temperature than normal, while the group is activated. When the group stops, the setpoint will return to its normal setting. Changing the setpoint while the group is running will make the group release the alternate setpoint control and revert back to the normal heater setting. Any changes that are made at that point will affect the normal heater setting. The next time the group is activated, the temperature will return to the group setpoint that was originally programmed in the Configuration Menu. To change the setpoint while the group is running, go to the Settings menu and press the +/- button while "Group Control" is displayed. The setpoint will change and be retained as the new normal heater setpoint. Super Chlorinate (requires external chlorinator) If a Hayward Swimpure or Goldline Aqua Rite chlorinator is used, the OnCommand can be programmed to Super Chlorinate the pool or spa while running a group command. When the group starts, the Super Chlorinate cycle will begin. Super Chlorinate will continue until the preset time expires (see Timers Menu/Super Chlorinate Hours) or until the group turns off. Changing the Super Chlorinate state using the Settings Menu, the Aqua Pod Super Chlorinate button, or a Super Chlorinate assigned Aux/Lights/Valve button will temporarily cancel the group's control of Super Chlorinate until the next time the group is activated. Variable Speed in Groups The OnCommand can be programmed to use alternate pump speeds while running a group command. This allows the pump to be set to a higher or lower speed than normal, while the group is activated. When the group stops, the speed will return to its normal setting. Changing the speed setting while the group is running will make the group release the alternate speed setting and revert back to the normal speed setting. Any changes that are made at that point will affect the normal speed setting. The next time the group is activated, the speed will return to the group speed setting that was originally programmed in the Configuration Menu. To change the speed setting while the group is running, go to the Settings menu and press the +/- button while "Group Control" is displayed. The speed setting will change to the normal speed setting. Accessing the Configuration Menus Configuring the OnCommand requires that you navigate through the Configuration Menu and input various information. For more detailed information about using the OnCommand menu system, refer to the Operation Manual. To access the Configuration Menu Configuration Menu-Locked Configuration Menu-Unlocked Press repeatedly until "Configuration Menu" is displayed Press BOTH buttons SIMULTANEOUSLY for 5 seconds to unlock Move to configuration menu items NOTE: The configuration menu automatically "locks" after 2 minutes of no buttons being pressed to prevent unauthorized people from changing the control logic inadvertently and possibly damaging the pool equipment or causing a "call back" to fix the configuration. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Heater Setpoints in Groups
The OnCommand can be programmed to use alternate heater setpoints (conventional and/or solar) while running
a group command. This allows the heater to be set to a higher or lower temperature than normal, while the group
is activated. When the group stops, the setpoint will return to its normal setting.
Changing the setpoint while the group is running will make the group release the alternate setpoint control and
revert back to the normal heater setting. Any changes that are made at that point will affect the normal heater
setting.
The next time the group is activated, the temperature will return to the group setpoint that was originally
programmed in the Configuration Menu. To change the setpoint while the group is running, go to the Settings menu
and press the +/- button while “Group Control” is displayed.
The setpoint will change and be retained as the new
normal heater setpoint.
Super Chlorinate (requires external chlorinator)
If a Hayward Swimpure or Goldline Aqua Rite chlorinator is used, the OnCommand can be programmed to Super
Chlorinate the pool or spa while running a group command. When the group starts, the Super Chlorinate cycle will
begin.
Super Chlorinate will continue until the preset time expires (see Timers Menu/Super Chlorinate Hours) or
until the group turns off.
Changing the Super Chlorinate state using the Settings Menu, the Aqua Pod Super
Chlorinate button, or a Super Chlorinate assigned Aux/Lights/Valve button will temporarily cancel the group’s
control of Super Chlorinate until the next time the group is activated.
Variable Speed in Groups
The OnCommand can be programmed to use alternate pump speeds while running a group command. This allows
the pump to be set to a higher or lower speed than normal, while the group is activated. When the group stops, the
speed will return to its normal setting.
Changing the speed setting while the group is running will make the group release the alternate speed setting and
revert back to the normal speed setting. Any changes that are made at that point will affect the normal speed
setting.
The next time the group is activated, the speed will return to the group speed setting that was originally
programmed in the Configuration Menu. To change the speed setting while the group is running, go to the Settings
menu and press the +/- button while “Group Control” is displayed.
The speed setting will change to the normal
speed setting.
Accessing the Configuration Menus
Configuring the OnCommand requires that you navigate through the Configuration Menu and input various infor-
mation.
For more detailed information about using the OnCommand menu system, refer to the Operation Manual.
To access the Configuration Menu
Configuration
Menu-Unlocked
Configuration
Menu-Locked
Press repeatedly until “Configuration Menu” is displayed
Move to configuration menu items
Press BOTH buttons SIMULTANEOUSLY for 5 seconds to unlock
NOTE: The configuration menu automatically “locks” after 2 minutes of no buttons being pressed to
prevent unauthorized people from changing the control logic inadvertently and possibly damaging
the pool equipment or causing a “call back” to fix the configuration.
15