HP 4400 HP StorageWorks Fabric OS 6.2.2e Release Notes (5697-0809, February 20 - Page 47
Fabric OS 6.2.2e fixes, Table 15 Fabric OS 6.2.2d closed defects
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
Table 15 Fabric OS 6.2.2d closed defects (continued) Closed defect summary Solution After upgrading to FOS 6.2.x firmware on 4 Gb switches, critical messages (CDR-1003) are posted to the RASLOG when a SupportSave operation is executed. Fixed in Fabric OS 6.2.2d. Workaround prior to update: Customers can ignore the CDR-1003 critical messages logged during SupportSave operations since they have been downgraded to warnings with this release. However, CDR-1003 critical messages for other operations should not be ignored. Path loss traces do not contain enough debugging Fixed in Fabric OS 6.2.2d. information when Access Gateway mode is enabled. Administration passwords are reset to the default password after upgrading from FOS 6.1.x to FOS 6.2.2c on all switches. Fixed in Fabric OS 6.2.2d. Some FA MIB counters/statistics are available through Fixed in Fabric OS 6.2.2d. the Command Line Interface, but they are not available through SNMP for all switches. Erroneous port faults may be reported in the RASLOG Fixed in Fabric OS 6.2.2d. after a switch with a large number of link-down events has been in operation for an extended period of time. Fabric OS 6.2.2e fixes Table 16 (page 47) lists defects closed in the Fabric OS 6.2.2e firmware release. Table 16 Fabric OS 6.2.2e closed defects Closed defect summary Solution The fans on an HP StorageWorks DC SAN Backbone Fixed in Fabric OS 6.2.2e. Director Switch may erroneously be flagged as bad Workaround prior to update: and get logged with a "[PLAT-5042], FAN I2C reset" error code in the Raslog, even though they are operating properly. Reseating the fans will allow the fans to recover from the faulty state. The Switchshow command reports the switch port state Fixed in Fabric OS 6.2.2e. as "Mod_Val" rather than "Online" after a switch reboot test and ISL fails to form. This applies to all switches except for the HP 8/8 Base (0) e-port SAN Switch, HP 8/8 (8)-ports Enabled SAN, HP 8/24 Base 16-ports Enabled SAN Switch Switch, HP 8/40 Base 24-ports Enabled SAN Switch, and the HP 8/40 Power Pack+ 24-ports SAN Switch. Access Gateway is not displayed by the DCFM client Fixed in Fabric OS 6.2.2e. when utilizing an EOS seed switch. When more than one RPC connection is established simultaneously on a switch with busy management applications, a race condition may cause multiple connections to free a shared object and trigger rpcd panic. Fixed in Fabric OS 6.2.2e. After performing a LOGO following a firmware Fixed in Fabric OS 6.2.2e. download the switch route is not properly established. The host cannot see the target because the PLOGI Accept from the HBA is dropped by the switch. The LED for online trunked F-Ports goes from a steady Fixed in Fabric OS 6.2.2e. green to off after a code upgrade or hareboot/hafailover. Fabric OS 6.2.2e fixes 47