Removing the Trailing Cable
View all HP C3180A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
Removing the Trailing Cable If you are installing a new trailing cable, make sure the main PCA is compatible with it. (Details D chapter 9.) 1 Remove the electronicsĆenclosure cover D page 6Ć5. 2 Remove the window D page 6Ć15. 3 Remove the center cover D page 6Ć16. 4 D/A1Ćsize plotters only: Open the flexible, DANGER HIGH VOLTAGE, insulation cover. Flex the cover to open it. Do not detach the cover from the plotter. 5 Disconnect the trailingĆcable connector from the main PCA. Trailing-cable connector 6 Remove the two screws that attach the toroid to the rear of the electronics enclosure. 7 Pull off the two endcaps of the toroid and remove the toroid from the trailing cable. Torx-10 C3187Ć90000 Removal and Replacement 6Ć29
1
Remove the electronicsĆenclosure
cover
D
page 6Ć5.
2
Remove the window
D
page 6Ć15.
3
Remove the center cover
D
page 6Ć16.
4
D/A1Ćsize plotters only: Open the
flexible, DANGER HIGH VOLTAGE,
insulation cover.
5
Disconnect the trailingĆcable connector
from the main PCA.
6
Remove the two screws that attach the
toroid to the rear of the electronics
enclosure.
Flex the cover to open it. Do not detach
the cover from the plotter.
Trailing-cable
connector
7
Pull off the two endcaps of the toroid and
remove the toroid from the trailing cable.
Torx-10
If you are installing a new trailing cable,
make sure the main PCA is compatible
with it. (Details
D
chapter 9.)
6Ć29
Removal and Replacement
C3187Ć90000