HP Designjet L28500 HP Designjet L28500 Printer Series - Site preparation guid - Page 11

Jumper configuration, 380–415 V, The L1, L2

Page 11 highlights

Table 2-5 Cable specifications (continued) Input voltage (line to line) 380-415 V~ (-10%+6%) External diameter range 14-25 mm 200-240 V~ (±10%) 14-25 mm The L1, L2, L3 (& N if any) wires must end with Ferrule terminals. The PE wire must end with a ring terminal (M6). Jumper configuration, 380-415 V ENWW Electrical configuration 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

Table 2-5
Cable specifications (continued)
Input voltage (line to line)
380–415 V~ (-10%+6%)
200–240 V~ (±10%)
External diameter range
14–25 mm
14–25 mm
The L1, L2, L3 (& N if any) wires must end with Ferrule terminals.
The PE wire must end with a ring terminal (M6).
Jumper configuration, 380–415 V
ENWW
Electrical configuration