HP Integrity Superdome 2 16-socket HP Integrity Superdome 2 Onboard Administra - Page 106
SHOW IOX STATUS, Xbar Fabric status
View all HP Integrity Superdome 2 16-socket manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
SHOW IOX STATUS • Command: SHOW IOX STATUS { ALL | }} • Description: Displays IO expansion enclosure status information: ◦ Status ◦ Power state of I/O bays ◦ UID state ◦ Diagnostic status ◦ Power subsystem status ◦ Cooling subsystem status ◦ Xbar Fabric status ◦ I/O slots state ◦ Thermal sensor status • Access level/Bay level: OA Administrator, OA Operator, OA User • Restrictions: You must be connected to the monarch OA. • Example: OA-001CC414F34F> show iox status 6 IOX 6: Health: OK Power: Bay 1: On Bay 2: Off Unit Identification LED: Off Diagnostic Status: Internal Data OK Redundancy OK Power Subsystem: Status: OK Redundancy State: Redundant Power Capacity: 4500 Watts DC Power Available: 4500 Watts DC Present Power: 247 Watts AC PS 1: OK PS 2: OK Cooling Subsystem: Status: OK Fans Good/Wanted/Needed: 4/4/3 Fan 1: 5486 RPM (30%) Fan 2: 5479 RPM (30%) Fan 3: 0 RPM (0%) Fan 4: 5488 RPM (30%) Xfabric Link Status: Link 1: OK 106 IOX enclosure management commands