HP Integrity Superdome 2 16-socket HP Integrity Superdome 2 Onboard Administra - Page 81
SHOW ENCLOSURE POWERSUPPLY, Current power output
View all HP Integrity Superdome 2 16-socket manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 81 highlights
Status: OK Display: On Name: BladeSystem c7000 Insight Display Spare Part Number: 441203-001 Manufacturer: HP Fw Version: 2.2.2 Diagnostic Status: Internal Data OK SHOW ENCLOSURE POWERSUPPLY IMPORTANT: In a complex with one or more failed power supplies it is possible for attempts to power on servers to fail if the resulting power allocation would result in the Power Redundancy Status becoming Failed. The administrator must explicitly reduce the redundancy setting to enable powering on servers prior to the failed power supplies being serviced. This applies to AC Redundant and Power Supply Redundant power modes. • Command: SHOW ENCLOSURE POWERSUPPLY {ALL | ]} • Description: Displays: ◦ Power supply status ◦ ac input status ◦ Capacity ◦ Current power output ◦ Serial number ◦ Product name ◦ Part number ◦ Spare part number ◦ Hardware revision for the specified power supply (if one is specified) ◦ Diagnostic status ◦ Range of power supplies, or for all power supplies (if ALL is specified). • Access level/Bay level: All • Restrictions: None • Example: SHOW ENCLOSURE POWERSUPPLY 81