HP P3005 Service Manual - Page 160

Close Top Cover And Front Door, Genuine Hp Supplies Designed - install black cartridge error

Page 160 highlights

Control panel message Description Recommended action alternates with To continue press The job is cancelled and no pages are printed. Cleaning... The device is processing the cleaning page. No action necessary. CLOSE TOP COVER Door switch SW501 is signalling that the cartridge door is open. If the cartridge door is open, the main motor will not rotate during device power-up. The wires for switch SW501 are hard-wired to the ECU. Verify that the wires from the ECU are installed on the correct terminals of switch SW501. CLOSE TOP COVER AND FRONT DOOR Door switch SW501 is signalling that the cartridge door is open. If the cartridge door is open, the main motor will not rotate during device power-up. The wires for switch SW501 are hard-wired to the ECU. Verify that the wires from the ECU are installed on the correct terminals of switch SW501. CODE CRC ERROR An error has occurred during a firmware upgrade. 1. Reinstall the firmware. 2. If the problem persists, contact HP Support. Creating...CLEANING PAGE The device is generating a cleaning page. 1. Load the cleaning page into tray 1. The device returns to the Ready state after the cleaning page is printed. 2. Press Menu. 3. Select PRINT QUALITY, and then press 4. Select PROCESS CLEANING PAGE, and then press DATA RECEIVED alternates with Ready The device received data and is waiting for a form feed. When the device receives another file, the message disappears. The device is paused. If the device is waiting for a form feed, press to continue. If the device is paused, press Stop to continue. GENUINE HP SUPPLIES DESIGNED FOR alternates with This genuine HP supply was not designed for this device and is not supported. The device can print with this supply, but print quality might be affected. Replace this supply with a genuine HP supply that is designed for this device. Ready Incorrect The PIN number is incorrect. Contact the network administrator. INFLATE FAILURE An error has occurred during a firmware upgrade. 1. Reinstall the firmware. 2. If the problem persists, contact HP Support. INSERT OR CLOSE TRAY XX A tray is open and the device is trying to print Close the tray indicated so that printing can from another tray. continue. INSTALL BLACK CARTRIDGE The device detects the print cartridge by 1. detecting a voltage differential within the cartridge. The photo-conductive drum connected to the high-voltage power supply 2. provides the reference with which to measure the differential. Verify that a print cartridge is installed in the device. Verify that the drum ground connector on the high-voltage power supply is correctly seated on the mechanical connector. 3. Verify that the cartridge mechanism functions correctly. When the cartridge is removed from the device, the 142 Chapter 6 Troubleshooting ENWW

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292

Control panel message
Description
Recommended action
alternates with
To continue press
The job is cancelled and no pages are
printed.
Cleaning...
The device is processing the cleaning page.
No action necessary.
CLOSE TOP COVER
Door switch SW501 is signalling that the
cartridge door is open. If the cartridge door is
open, the main motor will not rotate during
device power-up.
The wires for switch SW501 are hard-wired
to the ECU. Verify that the wires from the
ECU are installed on the correct terminals of
switch SW501.
CLOSE TOP COVER AND FRONT DOOR
Door switch SW501 is signalling that the
cartridge door is open. If the cartridge door is
open, the main motor will not rotate during
device power-up.
The wires for switch SW501 are hard-wired
to the ECU. Verify that the wires from the
ECU are installed on the correct terminals of
switch SW501.
CODE CRC ERROR
An error has occurred during a firmware
upgrade.
1.
Reinstall the firmware.
2.
If the problem persists, contact
HP Support.
Creating...CLEANING PAGE
The device is generating a cleaning page.
The device returns to the
Ready
state after
the cleaning page is printed.
1.
Load the cleaning page into tray 1.
2.
Press
Menu
.
3.
Select
PRINT QUALITY
, and then press
4.
Select
PROCESS CLEANING PAGE
,
and then press
DATA RECEIVED
alternates with
Ready
The device received data and is waiting for a
form feed. When the device receives another
file, the message disappears.
The device is paused.
If the device is waiting for a form feed,
press
to continue.
If the device is paused, press
Stop
to
continue.
GENUINE HP SUPPLIES DESIGNED FOR
<PROD>
alternates with
Ready
This genuine HP supply was not designed for
this device and is not supported. The device
can print with this supply, but print quality
might be affected.
Replace this supply with a genuine HP supply
that is designed for this device.
Incorrect
The PIN number is incorrect.
Contact the network administrator.
INFLATE FAILURE
An error has occurred during a firmware
upgrade.
1.
Reinstall the firmware.
2.
If the problem persists, contact
HP Support.
INSERT OR CLOSE TRAY XX
A tray is open and the device is trying to print
from another tray.
Close the tray indicated so that printing can
continue.
INSTALL BLACK CARTRIDGE
The device detects the print cartridge by
detecting a voltage differential within the
cartridge. The photo-conductive drum
connected to the high-voltage power supply
provides the reference with which to measure
the differential.
1.
Verify that a print cartridge is installed in
the device.
2.
Verify that the drum ground connector
on the high-voltage power supply is
correctly seated on the mechanical
connector.
3.
Verify that the cartridge mechanism
functions correctly. When the cartridge
is removed from the device, the
142
Chapter 6
Troubleshooting
ENWW