- For an HP System/e rack, install two #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers and two #10 alignment washers in the upper and lower hole locations of the right rail. Then install two #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers and two #10 alignment washers in the upper and lower hole locations of the left rail. See Figure 6. Figure 6: Assembling the outer rails (HP System/e rack) 5. Determine the number of #8-32 x 3/16-inch Phillips pan-head screws with thread lock required to assemble the inner rails by referring to Table 1. Table 1: Number of screws required to assemble the inner rails Switch SAN Switch 2/32 SAN Switch 2/16 SAN Switch 2/8 Number of #8-32 x 3/16-inch Screws 12 10 14 14 SAN Switch Rack Mount Kit Installation Instructions

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

14
SAN Switch Rack Mount Kit Installation Instructions
For an HP System/e rack, install two #10-32 x 1/2-inch Phillips pan-head
screws with captive star lock washers and two #10 alignment washers in
the upper and lower hole locations of the right rail. Then install two
#10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers
and two #10 alignment washers in the upper and lower hole locations of
the left rail. See
Figure 6
.
Figure 6:
Assembling the outer rails (HP System/e rack)
5.
Determine the number of #8-32 x 3/16-inch Phillips pan-head screws with
thread lock required to assemble the inner rails by referring to
Table 1
.
Table 1:
Number of screws required to assemble the inner rails
Switch
Number of #8-32 x 3/16-inch Screws
SAN Switch 2/32
12
SAN Switch 2/16
10
SAN Switch 2/8
14