fcFxPortClass3SeqDeliv 1.3.6.1.3.42.2.1.1.5.1.14
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
fcFxPortIntermixSupported 1.3.6.1.3.42.2.1.1.5.1.11 3 • Clas 3 (3) • Class 4 (4) • Class 5 (5) • Class 6 (6) fcFxPortIntermixSupported 1.3.6.1.3.42.2.1.1.5.1.11 A flag indicating whether the Fx_Port supports an Intermixed Dedicated Connection. Values Possible values are: • yes (1) • no (2) fcFxPortStackedConnMode 1.3.6.1.3.42.2.1.1.5.1.12 A value indicating the mode of stacked connect supported by the Fx_Port. fcFxPortClass2SeqDeliv 1.3.6.1.3.42.2.1.1.5.1.13 Values A flag indicating whether Class 2 sequential delivery is supported by the Fx_Port. Possible values are: • yes (1) • no (2) fcFxPortClass3SeqDeliv 1.3.6.1.3.42.2.1.1.5.1.14 Values A flag indicating whether Class 3 sequential delivery is supported by the Fx_Port. Possible values are: • yes (1) • no (2) fcFxPortHoldTime 1.3.6.1.3.42.2.1.1.5.1.15 The maximum time (in microseconds) that the Fx_Port holds a frame before discarding the frame if it is unable to deliver the frame. The value 0 means that the Fx_Port does not support this parameter. fcFxPortBaudRate 1.3.6.1.3.42.2.1.1.5.1.16 The FC-0 baud rate of the Fx_Port. The Brocade 12000, 24000, 48000, and DCX directors do not support this MIB variable. Fabric OS MIB Reference 95 53-1001339-01