HP StorageWorks 2/16V HP StorageWorks Fabric OS 5.3.2b release notes (5697-007 - Page 12

Within the context of FC Fast Write, L_Port is not supported in Fabric OS 5.3.0

Page 12 highlights

If the user tries to save more than 512 monitors using the perfCfgSave command, Performance monitoring some of the monitors may be lost. Management - Proxy If you using a Fabric OS 4.x switch as an API or SMI-S proxy to manage a 5.1.0 switches switch, you must be running Fabric OS 4.4.0d. Frame drops observed on FCIP slow links: • The frame drops occur when the FCIP tunnel bandwidth is set to 10 Base-T (10 Mb/s), E1 (1.048 Mb/s), or T1 (1.544 Mb/s). • With E1 or T1, frames drop even without an impaired link. • With 10 Base-T, frame drops may be observed when a low impairment is put to the link. FCIP The portperfshow command indicated incorrect (smaller) bidirectional throughput on the FCIP tunnel when Fast Write/Tape Pipelining is enabled. Fast Write/Tape Pipelining did not inform user when it failed due to multiple equal paths configured on 2 GbE ports. Backup jobs initiated from the Symantec BackupExec application slowed noticeably after adding significant I/O traffic from regular hosts and targets to the FCIP tunnel. A port-based routing policy must be used for Tape devices. portcfgdefault command function change for the Brocade 4Gb SAN Switch for HP c-Class BladeSystem Beginning with Fabric OS 5.2.1b, the portcfgdefault command now resets the configuration to HP factory default port settings. Broadcast Zones In Fabric OS 5.3.0 and later, a zone with the name broadcast (case-sensitive) is a special zone for setting up recipients of broadcast packets. In Fabric OS versions earlier than 5.3.0, a zone named broadcast does not have special significance. Therefore, you must make sure that if a broadcast zone is configured, the active and standby CPs use the same Fabric OS version. Otherwise, an HA failover might change the zone configuration. Faulty SFPs An external port with a faulty SFP will be disabled, then enabled once a good SFP is inserted. However, the port will still show as faulty even though it is healthy. To get the correct healthy indication, after enabling the port with the good SFP, remove and reinsert it and the port will then show as healthy. FC Fast Write Note the following important information when using FC Fast Write: • Only WWN zone (including normal zone and FC Fast Write zone) is supported on FC Fast Write enabled port. • Only single device loop port is supported. • NPIV (Access Gateway, for example) port is not supported. • FCR backbone devices are not supported. That is FC Fast Write should not be enabled on backbone devices. • FCR edge to edge support is limited by all the target devices on given edge fabric that host talks to should be connected to a 400 MP Router or B-series MP Router Blade in FC Fast Write mode. FC Fast Write should not be enabled on ports when testing the remote mirror application. • When a very high volume of traffic is being sent by host, FC Fast Write I/Os may time out and frame may be dropped. • Within the context of FC Fast Write, L_Port is not supported in Fabric OS 5.3.0 and later. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

If the user tries to save more than 512 monitors using the
perfCfgSave
command,
some of the monitors may be lost.
Performance monitoring
If you using a Fabric OS 4.x switch as an API or SMI-S proxy to manage a 5.1.0
switch, you must be running Fabric OS 4.4.0d.
Management
Proxy
switches
Frame drops observed on FCIP slow links:
The frame drops occur when the FCIP tunnel bandwidth is set to 10 Base-T (10
Mb/s), E1 (1.048 Mb/s), or T1 (1.544 Mb/s).
With E1 or T1, frames drop even without an impaired link.
With 10 Base-T, frame drops may be observed when a low impairment is put to
the link.
The
portperfshow
command indicated incorrect (smaller) bidirectional throughput
on the FCIP tunnel when Fast Write/Tape Pipelining is enabled.
Fast Write/Tape Pipelining did not inform user when it failed due to multiple equal
paths configured on 2 GbE ports.
Backup jobs initiated from the Symantec BackupExec application slowed noticeably
after adding significant I/O traffic from regular hosts and targets to the FCIP tunnel.
A port-based routing policy must be used for Tape devices.
FCIP
Beginning with Fabric OS 5.2.1b, the
portcfgdefault
command now resets the
configuration to HP factory default port settings.
portcfgdefault
command function
change for the Brocade
4Gb SAN Switch for
HP c-Class BladeSystem
In Fabric OS 5.3.0 and later, a zone with the name broadcast (case-sensitive) is a
special zone for setting up recipients of broadcast packets. In Fabric OS versions
earlier than 5.3.0, a zone named
broadcast
does not have special significance.
Therefore, you must make sure that if a broadcast zone is configured, the active and
standby CPs use the same Fabric OS version. Otherwise, an HA failover might
change the zone configuration.
Broadcast Zones
An external port with a faulty SFP will be disabled, then enabled once a good SFP
is inserted. However, the port will still show as faulty even though it is healthy. To
get the correct healthy indication, after enabling the port with the good SFP, remove
and reinsert it and the port will then show as healthy.
Faulty SFPs
Note the following important information when using FC Fast Write:
Only WWN zone (including normal zone and FC Fast Write zone) is supported
on FC Fast Write enabled port.
Only single device loop port is supported.
NPIV (Access Gateway, for example) port is not supported.
FCR backbone devices are not supported. That is FC Fast Write should not be
enabled on backbone devices.
FCR edge to edge support is limited by all the target devices on given edge
fabric that host talks to should be connected to a 400 MP Router or B-series MP
Router Blade in FC Fast Write mode. FC Fast Write should not be enabled on
ports when testing the remote mirror application.
When a very high volume of traffic is being sent by host, FC Fast Write I/Os
may time out and frame may be dropped.
Within the context of FC Fast Write, L_Port is not supported in Fabric OS 5.3.0
and later.
FC Fast Write