HP StorageWorks 2/16V HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N Fabric OS - Page 13

Hardware Notes, Table 3: Small Form Factor Pluggables, Table 4: Fabric OS Area Information - storageworks san switch firmware

Page 13 highlights

Important Notes Hardware Notes Table 3 lists important hardware related information for the HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V and SAN Switch 2/16N models. Table 3: Small Form Factor Pluggables S P F Part Number Description* 221470-B21 500m 2 Gb SFF-SW Tmcvr Kit DS-DMSHT-AA 500 m 2 Gb SFF-SW 300834-B21 292003-001 A6515A DS-DMLNG-AA 10 km LD Opti Tran ALL 300835-B21 292004-001 A6516A DS-DMEXT-AA 35 km ExtRch Opti K ALL 300836-B21 292005-001 * SFF = small form factor. Max Distance at 2 GB 300 m 300 m 10 km 35 km Firmware Notes Table 4 lists important firmware related information for the HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V and SAN Switch 2/16N models. Table 4: Fabric OS Area Information Fabric OS Area Extended links Fabric configuration Description For 50-km extended links, you have a choice of configuring a port as an LD port or an L1 port. LD ports maintain full link speeds of 103 Mbit/sec. L1 ports have link speeds of 99 Mbit/sec; however, you can configure all four ports of a quad as L1 ports, but you can configure only one port in a quad as an LD port. During fabric configuration, the countdown message that used to appear on the console is removed starting with Fabric OS v2.6.2, v3.1.2, and v4.2.x. The fabric reconfiguration message is now captured in the error log. For details, refer to the diagnostic messages in the HP StorageWorks Diagnostic and System Error Messages 4.2.x Reference Guide. SAN Switch 2/8V, 2/16V, 2/16N Fabric OS 4.2.x Release Notes 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

Important Notes
13
SAN Switch 2/8V, 2/16V, 2/16N Fabric OS 4.2.x Release Notes
Hardware Notes
Table 3
lists important hardware related information for the HP StorageWorks
SAN Switch 2/8V, SAN Switch 2/16V and SAN Switch 2/16N models.
Firmware Notes
Table 4
lists important firmware related information for the HP StorageWorks
SAN Switch 2/8V, SAN Switch 2/16V and SAN Switch 2/16N models.
Table 3:
Small Form Factor Pluggables
Part Number
Description*
Max
Distance at
2 GB
221470-B21
500m 2 Gb SFF-SW Tmcvr Kit
300 m
DS-DMSHT-AA
300834-B21
292003-001
A6515A
500 m 2 Gb SFF-SW
300 m
DS-DMLNG-AA
300835-B21
292004-001
A6516A
10 km LD Opti Tran ALL
10 km
DS-DMEXT-AA
300836-B21
292005-001
35 km ExtRch Opti K ALL
35 km
* SFF = small form factor.
Table 4:
Fabric OS Area Information
Fabric OS Area
Description
Extended links
For 50-km extended links, you have a choice of configuring a port as an LD
port or an L1 port. LD ports maintain full link speeds of 103 Mbit/sec.
L1
ports have link speeds of 99 Mbit/sec; however, you can configure all four
ports of a quad as L1 ports, but you can configure only one port in a quad
as an LD port.
Fabric configuration
During fabric configuration, the countdown message that used to appear on
the console is removed starting with Fabric OS v2.6.2, v3.1.2, and v4.2.x.
The fabric reconfiguration message is now captured in the error log. For
details, refer to the diagnostic messages in the
HP StorageWorks Diagnostic
and System Error Messages 4.2.x Reference Guide
.