HP StorageWorks 2/16V HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N Fabric OS - Page 18

HP StorageWorks SAN Switch 2/8V and 2/16V Installation Guide - storageworks 2000

Page 18 highlights

Documentation Updates HP StorageWorks SAN Switch 2/8V and 2/16V Installation Guide On page 32, Table 6: Rack mount kit rails and rail mounting hardware: ■ Remove the following screw description: (14) #8-32 x 3/16-inch Phillips pan-head screw with thread lock ■ Insert the following screw descriptions: (14) 8-32 x 5/16-inch Phillips pan-head SEMS screw for use with the SAN Switch 2/8, SAN Switch 2/8V, SAN Switch 2/16, SAN Switch 2/16V and SAN Switch 2/16N (14) #8-32 x 3/16-inch Phillips pan-head screw with thread lock for the SAN Switch 2/32 HP StorageWorks Fabric OS 4.2.x Command Reference Guide The following commands have been modified: ■ configure ■ portCfgGPort ■ portCfgLongDistance ■ portCfgislMode Each change is detailed in the sections that follow. configure Change the Domain, R_A_TOV, and E_D_TOV fields as follows: Field Domain R_A_TOV E_D_TOV Default 1 10000 2000 Range Varies E_D_TOV * 2 to 12000 1000 to R_A_TOV / 2 portCfgLongDistance Add a Note regarding the portCfgislMode command, as follows: Note: portCfgislMode and portCfgLongDistance cannot both be enabled at the same time; otherwise, fabric segmentation occurs. 18 SAN Switch 2/8V, 2/16V, 2/16N Fabric OS 4.2.x Release Notes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22

Documentation Updates
18
SAN Switch 2/8V, 2/16V, 2/16N Fabric OS 4.2.x Release Notes
HP StorageWorks SAN Switch 2/8V and 2/16V Installation Guide
On page 32,
Table 6: Rack mount kit rails and rail mounting hardware
:
Remove the following screw description:
(14) #8-32 x 3/16-inch Phillips pan-head screw with thread lock
Insert the following screw descriptions:
(14) 8-32 x 5/16-inch Phillips pan-head SEMS screw for use with the SAN
Switch 2/8, SAN Switch 2/8V, SAN Switch 2/16, SAN Switch 2/16V and
SAN Switch 2/16N
(14) #8-32 x 3/16-inch Phillips pan-head screw with thread lock for the SAN
Switch 2/32
HP StorageWorks Fabric OS 4.2.x Command Reference Guide
The following commands have been modified:
configure
portCfgGPort
portCfgLongDistance
portCfgislMode
Each change is detailed in the sections that follow.
configure
Change the Domain, R_A_TOV, and E_D_TOV fields as follows:
portCfgLongDistance
Add a Note regarding the
portCfgislMode
command, as follows:
Note:
portCfgislMode
and
portCfgLongDistance
cannot both be enabled at
the same time; otherwise, fabric segmentation occurs.
Field
Default
Range
Domain
1
Varies
R_A_TOV
10000
E_D_TOV * 2 to 12000
E_D_TOV
2000
1000 to R_A_TOV / 2