HP StorageWorks 2/32 Brocade Fabric OS Documentation Addendum - Supporting Fab - Page 76
Updates to the Introduction New AG System Messages, AG-1001, Introduction
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
2 Updates to the Introduction Chapter Updates to the Introduction Chapter Add the following row to the System Modules Descriptions tabe on page 1-15. AG Access Gateway mode messages of the Fabric OS. New Chapter, AG System Messages Add a new chapter titled AG System Messages after the Introduction and before the AUTH System Messages; it contains all the new messages for the feature, Brocade Access Gateway mode. AG-1001 Message , [AG-1001], ,, ERROR, , N_Port is connected to a fabric port that does not support NPIV Probable Cause Recommended Action Severity Indicates that the fabric port to which Access Gateway is connected does not support NPIV. Enable NPIV on the port connected to the Access Gateway using the portCfgNpivPort command on the fabric switch. Refer Fabric OS Command Reference Manual for more information on this command. ERROR AG-1002 Message , [AG-1002], ,, WARNING, , Unable to find alternate N_Port during fail over for N_Port Probable Cause Recommended Action Severity Indicates that the F_Ports could not be failed over because no other N_Ports are configured or that the fabric was unstable during the failover attempt. Verify whether or not other N_Ports are configured. If the message persists, run supportFtp to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING 2-2 Fabric OS Documentation Addendum Publication Number: 53-1000429-01-HP